MOC306x. ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified). ZERO CROSSING CHARACTERISTICS. Parameter. Symbol

MOC306x ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified) ZERO CROSSING CHARACTERISTICS Parameter Symbol

Modelllinie für dieses Datenblatt

Textversion des Dokuments

MOC306x ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified) ZERO CROSSING CHARACTERISTICS Parameter Symbol Test Condition Min Typ. Max Unit
Inhibit Voltage VINH IF = Rated IFT, 5 20 V MT1-MT2 Voltage above which device will not trigger Leakage Current at IDRM2 IF = Rated IFT, 500 μA Inhibit State V DRM = 600V, Off-state
ISOLATION Parameter Symbol Test Condition Min Typ. Max Unit
Isolation Voltage VISO RH = 40 to 60%, t = 1 min 5000 VRMS Input-Output Note 3 Note 1 : Test Voltage must be applied within dv/dt rating. Note 2 : Guaranteed to trigger at an IF value less than or equal to max IFT, recommended IF lies between Rated IFT to Absolute Max IF. Note 3 : Measured with input leads shorted together and output leads shorted together. 3 05/02/2018 DD93230