Datasheet SFH610A, SFH6106 (Vishay) - 4

HerstellerVishay
BeschreibungOptocoupler, Phototransistor Output, High Reliability, 5300 VRMS
Seiten / Seite9 / 4 — SFH610A, SFH6106. SWITCHING CHARACTERISTICS PARAMETER. TEST CONDITION. …
Dateiformat / GrößePDF / 178 Kb
DokumentenspracheEnglisch

SFH610A, SFH6106. SWITCHING CHARACTERISTICS PARAMETER. TEST CONDITION. PART. SYMBOL. MIN. TYP. MAX. UNIT. Note

SFH610A, SFH6106 SWITCHING CHARACTERISTICS PARAMETER TEST CONDITION PART SYMBOL MIN TYP MAX UNIT Note

Modelllinie für dieses Datenblatt

Textversion des Dokuments

SFH610A, SFH6106
www.vishay.com Vishay Semiconductors
SWITCHING CHARACTERISTICS PARAMETER TEST CONDITION PART SYMBOL MIN. TYP. MAX. UNIT
SFH610A-1 tf - 11 - μs SFH6106-1 SFH610A-2 tf - 14 - μs SFH6106-2 Fall time SFH610A-3 tf - 14 - μs SFH6106-3 SFH610A-4 tf - 15 - μs SFH6106-4 SFH610A-1 ton - 3 - μs SFH6106-1 SFH610A-2 ton - 4.2 - μs SFH6106-2 Turn-on time SFH610A-3 ton - 4.2 - μs SFH6106-3 SFH610A-4 ton - 6 - μs SFH6106-4 SFH610A-1 toff - 18 - μs SFH6106-1 SFH610A-2 toff - 23 - μs SFH6106-2 Turn-off time SFH610A-3 toff - 23 - μs SFH6106-3 SFH610A-4 toff - 25 - μs SFH6106-4
Note
• All values presented are typical values.
SAFETY AND INSULATION RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT
Climatic classification According to IEC 68 part 1 55 / 100 / 21 Comparative tracking index Insulation group IIIa CTI 175 Maximum rated withstanding isolation voltage According to UL1577, t = 1 min VISO 4420 VRMS Tested withstanding isolation voltage According to UL1577, t = 1 s VISO 5300 VRMS Maximum transient isolation voltage According to DIN EN 60747-5-5 VIOTM 10 000 V Maximum repetitive peak isolation voltage According to DIN EN 60747-5-5 VIORM 890 V VIO = 500 V, Tamb = 25 °C RIO ≥ 1012 Ω Isolation resistance VIO = 500 V, Tamb = 100 °C RIO ≥ 1011 Ω Output safety power PSO 400 mW Input safety current ISI 275 mA Input safety temperature TSI 175 °C Creepage distance ≥ 7 mm DIP-4 / SMD-4 Clearance distance ≥ 7 mm Creepage distance ≥ 8 mm DIP-4, 400 mil / SMD-4, 400 mil Clearance distance ≥ 8 mm Insulation thickness DTI ≥ 0.4 mm
Note
• As per IEC 60747-5-5, § 7.4.3.8.2, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with the safety ratings shall be ensured by means of protective circuits. Rev. 2.5, 28-Mar-18
4
Document Number: 83666 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000