ADXRS649Data SheetABSOLUTE MAXIMUM RATINGS Table 2.RATE SENSITIVE AXISParameter Rating The ADXRS649 is a z-axis rate-sensing device (also called a yaw Acceleration (Any Axis, 0.5 ms) rate-sensing device). It produces a positive going output voltage Unpowered 10,000 g for clockwise rotation about the axis normal to the package top, Powered 10,000 g that is, clockwise when looking down at the package lid. VDD, AVCC −0.3 V to +6.0 V VRATIO AVCC RATERATEOUT ST1, ST2 AVCC AXISAVCC = 5V Output Short-Circuit Duration Indefinite 4.75V (Any Pin to Common) LONGITUDINALAXIS+ Operating Temperature Range −55°C to +125°C VRATIO/27 Storage Temperature Range −65°C to +150°C RATE IN10.25V Stresses above those listed under the Absolute Maximum A B C D E F GA1 002 3- Ratings may cause permanent damage to the device. This is a GNDLATERAL AXIS 0957 stress rating only; functional operation of the device at these or Figure 2. RATEOUT Signal Increases with Clockwise Rotation any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect ESD CAUTION device reliability. Drops onto hard surfaces can cause shocks of greater than 10,000 g and can exceed the absolute maximum rating of the device. Care should be exercised in handling to avoid damage. Rev. B | Page 4 of 12 Document Outline Features Applications General Description Functional Block Diagram Revision History Specifications Absolute Maximum Ratings Rate Sensitive Axis ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Theory of Operation Setting the Bandwidth Temperature Output and Calibration Modifying the Measurement Range Null Bias Adjustment Self-Test Function Continuous Self-Test Outline Dimensions Ordering Guide