Datasheet AD9683 (Analog Devices) - 6
Hersteller | Analog Devices |
Beschreibung | 14-Bit, 170 MSPS/250 MSPS, JESD204B, Analog-to-Digital Converter |
Seiten / Seite | 45 / 6 — Data Sheet. AD9683. ADC AC SPECIFICATIONS. Table 2. AD9683-170. … |
Revision | D |
Dateiformat / Größe | PDF / 1.4 Mb |
Dokumentensprache | Englisch |
Data Sheet. AD9683. ADC AC SPECIFICATIONS. Table 2. AD9683-170. AD9683-250. Parameter1. Temperature. Min. Typ. Max. Unit
Modelllinie für dieses Datenblatt
Textversion des Dokuments
link to page 7
Data Sheet AD9683 ADC AC SPECIFICATIONS
AVDD = 1.8 V, DRVDD = 1.8 V, DVDD = 1.8 V, maximum sample rate for speed grade, VIN = −1.0 dBFS differential input, 1.75 V p-p full-scale input range, default SPI, unless otherwise noted.
Table 2. AD9683-170 AD9683-250 Parameter1 Temperature Min Typ Max Min Typ Max Unit
SIGNAL-TO-NOISE-RATIO (SNR) fIN = 30 MHz 25°C 72.3 72.1 dBFS fIN = 90 MHz 25°C 72.0 71.7 dBFS Full 71 dBFS fIN = 140 MHz 25°C 71.3 71.3 dBFS fIN = 185 MHz 25°C 70.5 70.6 dBFS Full 70.0 dBFS fIN = 220 MHz 25°C 70.0 70.0 dBFS SIGNAL-TO-NOISE AND DISTORTION (SINAD) fIN = 30 MHz 25°C 71.3 70.9 dBFS fIN = 90 MHz 25°C 70.8 70.6 dBFS Full 69.9 dBFS fIN = 140 MHz 25°C 70.2 70.1 dBFS fIN = 185 MHz 25°C 69.5 69.5 dBFS Full 68.7 dBFS fIN = 220 MHz 25°C 68.8 68.7 dBFS EFFECTIVE NUMBER OF BITS (ENOB) fIN = 30 MHz 25°C 11.5 11.5 Bits fIN = 90 MHz 25°C 11.5 11.4 Bits fIN = 140 MHz 25°C 11.4 11.4 Bits fIN = 185 MHz 25°C 11.3 11.3 Bits fIN = 220 MHz 25°C 11.1 11.1 Bits SPURIOUS-FREE DYNAMIC RANGE (SFDR) fIN = 30 MHz 25°C 94 87 dBc fIN = 90 MHz 25°C 89 86 dBc Full 81 dBc fIN = 140 MHz 25°C 94 87 dBc fIN = 185 MHz 25°C 89 88 dBc Full 80 dBc fIN = 220 MHz 25°C 87 86 dBc WORST SECOND OR THIRD HARMONIC fIN = 30 MHz 25°C −94 −87 dBc fIN = 90 MHz 25°C −89 −86 dBc Full −81 dBc fIN = 140 MHz 25°C −94 −87 dBc fIN = 185 MHz 25°C −89 −88 dBc Full −80 dBc fIN = 220 MHz 25°C −87 −86 dBc WORST OTHER (HARMONIC OR SPUR) fIN = 30 MHz 25°C −99 −95 dBc fIN = 90 MHz 25°C −92 −94 dBc Full −83 dBc fIN = 140 MHz 25°C −96 −94 dBc fIN = 185 MHz 25°C −94 −93 dBc Full −82 dBc fIN = 220 MHz 25°C −95 −92 dBc Rev. D | Page 5 of 44 Document Outline FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAM GENERAL DESCRIPTION TABLE OF CONTENTS REVISION HISTORY PRODUCT HIGHLIGHTS SPECIFICATIONS ADC DC SPECIFICATIONS ADC AC SPECIFICATIONS DIGITAL SPECIFICATIONS SWITCHING SPECIFICATIONS TIMING SPECIFICATIONS Timing Diagrams ABSOLUTE MAXIMUM RATINGS THERMAL CHARACTERISTICS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS EQUIVALENT CIRCUITS THEORY OF OPERATION ADC ARCHITECTURE ANALOG INPUT CONSIDERATIONS Input Common Mode Differential Input Configurations VOLTAGE REFERENCE CLOCK INPUT CONSIDERATIONS Nyquist Clock Input Options RF Clock Input Options Input Clock Divider Clock Duty Cycle Jitter Considerations POWER DISSIPATION AND STANDBY MODE DIGITAL OUTPUTS JESD204B TRANSMIT TOP LEVEL DESCRIPTION JESD204B Overview JESD204B Synchronization Details CGS Phase ILAS Phase Data Transmission Phase Link Setup Parameters Disable Lane Before Changing Configuration Configure Detailed Options Check FCHK, Checksum of JESD204B Interface Parameters Set Additional Digital Output Configuration Options Reenable Lane After Configuration Frame and Lane Alignment Monitoring and Correction Digital Outputs and Timing ADC OVERRANGE AND GAIN CONTROL ADC Overrange (OR) Gain Switching Fast Threshold Detection (FD) DC CORRECTION (DCC) DC CORRECTION BANDWIDTH DC CORRECTION READBACK DC CORRECTION FREEZE DC CORRECTION ENABLE BITS SERIAL PORT INTERFACE (SPI) CONFIGURATION USING THE SPI HARDWARE INTERFACE SPI ACCESSIBLE FEATURES MEMORY MAP READING THE MEMORY MAP REGISTER TABLE Open and Reserved Locations Default Values Logic Levels Transfer Register Map MEMORY MAP REGISTER TABLE MEMORY MAP REGISTER DESCRIPTIONS PDWN Modes (Address 0x08) Output Mode (Address 0x14) SYNCINB±/SYSREF± Control (Address 0x3A) DC Correction Control (Address 0x40) DC Correction Value 0 (Address 0x41) DC Correction Value 1 (Address 0x42) Fast Detect Control (Address 0x45) Fast Detect Upper Threshold (Address 0x47 and Address 0x48) Fast Detect Lower Threshold (Address 0x49 and Address 0x4A) Fast Detect Dwell Time (Address 0x4B and Address 0x4C) JESD204B Quick Configuration (Address 0x5E) JESD204B Link Control 1 (Address 0x5F) JESD204B Link Control 2 (Address 0x60) JESD204B Link Control 3 (Address 0x61) JESD204B Device Identification (DID) Configuration (Address 0x64) JESD204B Bank Identification (BID) Configuration (Address 0x65) JESD204B Lane Identification (LID) Configuration (Address 0x67) JESD204B Scrambler (SCR) and Lane (L) Configuration (Address 0x6E) JESD204B Parameter, F (Address 0x6F, Read Only) JESD204B Parameter, K (Address 0x70) JESD204B Parameter, M (Address 0x71) JESD204B Parameters, N/CS (Address 0x72) JESD204B Parameter, Subclass/N’ (Address 0x73) JESD204B Samples per Converter per Frame Cycle (S) (Address 0x74) JESD204B Parameters HD and CF (Address 0x75) JESD204B Reserved 1 (Address 0x76) JESD204B Reserved 2 (Address 0x77) JESD204B Checksum (Address 0x79) JESD204B Output Driver Control (Address 0x80) JESD204B LMFC Offset (Address 0x8B) JESD204B Preemphasis (Address 0xA8) APPLICATIONS INFORMATION DESIGN GUIDELINES Power and Ground Recommendations Exposed Pad Thermal Heat Slug Recommendations VCM SPI Port OUTLINE DIMENSIONS ORDERING GUIDE