Datasheet ASR (Abracon)

HerstellerAbracon
BeschreibungSaw resonator 915 MHz SMD
Seiten / Seite1 / 1 — SMD ONE PORT 915 MHz SAW RESONATOR. Pb RoHS. Compliant. STANDARD …
Dateiformat / GrößePDF / 551 Kb
DokumentenspracheEnglisch

SMD ONE PORT 915 MHz SAW RESONATOR. Pb RoHS. Compliant. STANDARD SPECIFICATIONS:. Item. Units. Minimum Typical Maximum

Datasheet ASR Abracon

Modelllinie für dieses Datenblatt

ASR

Textversion des Dokuments

SMD ONE PORT 915 MHz SAW RESONATOR
ASR915E
Pb RoHS Compliant
5 x 5 x 1.35mm
STANDARD SPECIFICATIONS:
a t a D m i w d e r u s a e h t e c r u o S m I e c n a d e p 0 5 = s Z Load Impedance ZL=50 TA=25°C
Item Units Minimum Typical Maximum Center Frequency Fo
MHz 914.85 915.000 915.15
Insertion Attenuation
@ 915MHz dB - 1.5 2.5
Unloaded
-- 8000.0 --
Quality Factor
-
50

loaded
-- 1300.0 -- Turnover Temperature °C -- 25.0 --
Temperature Stability
Turnover Frequency KHz -- Fo -- Freq. Temp. Coefficient ppm/°C2 -- 0.032 --
Frequency Aging
ppm/year -- ±10 --
DC Insulation Resistance
MΩ 1 -- Motional Resistance R1 Ω -- 18.0 --
RF Equivalent RLC
Motional Inductance L1 µH -- 25.2 --
Model
Motional Capacitance C1 fF -- 1.2 -- Shunt Capacitance C0 pF -- 1.6 --
Operating temp.
°C -40°C to +85°C
Storage temp.
°C -45°C to +85°C
Max. Rating
DC voltage V ±10
RF Power Dissipation
dBm 0
FREQUENCY RESPONSE: OUTLINE DRAWING:
0.20±.008 0.1±.006 (5.0±0.2) (2.54±0.15) 4 5 3 80 )2 .0 . ± 0 0 ±0 6 2 0.05 .2 . 0 5( 7 1 (1.27) 8 0.047 (1.20) 0.053 8 (1.35) 0.08 (2.08) 7 1
TEST CIRCUIT:
6 2 5 3 0.47 4 0.024 (1.20) (0.60) Dimensions: inch (mm)
MARKING: PIN NO. CONNECTIONS
- 915R (915 Frequency in MHz) 1 Input GND - A ZYX (ZY: Date code Z for month 2 Input from A to L; Y for year, 5 Output GND 6 Output I.e. 4 for 2004 3,7 To be GNDed X: Traceability code) 4,8 Case GND
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information. ABRACON IS Visit www.abracon.com for Terms & Conditions of Sale ISO 9001 / QS 9000 ISO 9001:2008 30332 Esperanza, Rancho Santa Margarita, California 92688 CERTIFIED R tel 949-546-8000 | fax 949-546-8001 | www.abracon.com