Datasheet LM4041 (Diodes) - 2

HerstellerDiodes
BeschreibungPrecision Micropower Shunt Voltage References
Seiten / Seite7 / 2 — LM4041. PRECISION MICROPOWER SHUNT VOLTAGE REFERENCES. Absolute Maximum …
Dateiformat / GrößePDF / 259 Kb
DokumentenspracheEnglisch

LM4041. PRECISION MICROPOWER SHUNT VOLTAGE REFERENCES. Absolute Maximum Ratings. Description. Rating. Unit. ESD Ratings

LM4041 PRECISION MICROPOWER SHUNT VOLTAGE REFERENCES Absolute Maximum Ratings Description Rating Unit ESD Ratings

Modelllinie für dieses Datenblatt

Textversion des Dokuments

LM4041 PRECISION MICROPOWER SHUNT VOLTAGE REFERENCES Absolute Maximum Ratings Description Rating Unit
Continuous Reverse Current (IR) 20 mA Continuous Forward Current (IF) 10 mA Maximum Output Voltage (LM4041_ADJ) 15 V Junction Temperature -40 to 155 °C Storage Temperature -55 to 150 °C
ESD Ratings
Human Body Model 4000 V Machine Model 200 V These are stress ratings only. Operation outside the absolute maximum ratings may cause device failure. Operation at the absolute maximum rating, for extended periods may reduce device reliability. Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when handling and transporting these devices.
Package Thermal Data P Package θ DIS JA TA = 25°C, TJ = 150°C
SOT23 380°C/W 330mW SC70-5 420°C/W 300mW
Recommended Operating Conditions Parameter Min Max Units
Reverse Current 0.06 12 mA Output Voltage Range 1.24 10 V Operating Ambient Temperature Range -40 125 °C LM4041 2 of 7 September 2011 Document number: DS32020 Rev. 8 - 2
www.diodes.com
© Diodes Incorporated