link to page 8 link to page 7 Data SheetADG701L/ADG702LTERMINOLOGY RONtON Ohmic resistance between D and S. Delay between applying the digital control input and the output switching on. See Figure 16. RFLAT(ON) Flatness is defined as the difference between the maximum and tOFF minimum value of on resistance as measured over the specified Delay between applying the digital control input and the output analog signal range. switching off. IS (OFF)Off Isolation Source leakage current with the switch off. A measure of unwanted signal coupling through an off switch. ID (OFF)Charge Injection Drain leakage current with the switch off. A measure of the glitch impulse transferred from the digital I input to the analog output during switching. D, IS (ON) Channel leakage current with the switch on. BandwidthV The frequency at which the output is attenuated by −3 dB. D (VS) Analog voltage on Terminal D and Terminal S. On ResponseC The frequency response of the on switch. S (OFF) Off switch source capacitance. On LossC The voltage drop across the on switch, seen in Figure 11 as the D (OFF) Off switch drain capacitance. number of decibels the signal is away from 0 dB at very low frequencies. CD, CS (ON) On switch capacitance. Rev. A | Page 9 of 12 Document Outline Features Applications General Description Functional Block Diagrams Product Highlights Revision History Specifications Absolute Maximum Ratings ESD Caution Pin Configurations and Function Descriptions Typical Performance Characteristics Test Circuits Terminology Applications Information Supply Voltages Bandwidth Off Isolation Outline Dimensions Ordering Guide