link to page 14 link to page 15 link to page 15 link to page 15 link to page 15 link to page 15 link to page 15 ADG4612/ADG4613Parameter25°C−40°C to +85°CUnitTest Conditions/Comments Break-Before-Make Time Delay, tD 20 ns typ RL = 50 Ω, CL = 35 pF (ADG4613 Only) 3 ns min VS1 = VS2 = 3 V; see Figure 26 Fault Response Time 295 ns typ VS = 2 V to 8 V, RL = 300 Ω, CL = 35 pF Fault Recovery Time 1.2 μs typ VS = 2 V to 8 V, RL = 300 Ω, CL = 35 pF Threshold Voltage, VT 1.8 V typ Charge Injection 225 pC typ VS = 0 V, RS = 0 Ω, CL = 1 nF; see Figure 27 Off Isolation −54 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz; see Figure 28 Channel-to-Channel Crosstalk −71 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz; see Figure 29 Total Harmonic Distortion + Noise, THD + N 0.13 % typ RL = 110 Ω, 6 V p-p, f = 20 Hz to 20 kHz; see Figure 31 Insertion Loss −0.5 dB typ RL = 50 Ω, CL = 5 pF; f = 1 MHz; see Figure 30 −3 dB Bandwidth 293 MHz typ RL = 50 Ω, CL = 5 pF; see Figure 30 CS (Off ) 13 pF typ VS = 0 V, f = 1 MHz CD (Off ) 13 pF typ VS = 0 V, f = 1 MHz CD (On), CS (On) 50 pF typ VS = 0 V, f = 1 MHz POWER REQUIREMENTS Normal Mode Digital inputs = 0 V or VDD IDD 90 μA typ VDD = +5.5 V, VSS = −5.5 V 140 165 μA max ISS 27 μA typ VDD = +5.5 V, VSS = −5.5 V 50 58 μA max Isolation Mode VDD = +5.5 V, VSS = −5.5 V or floating IDD 90 μA typ Digital inputs = 0 V or 5.5 V 140 165 μA max VS = −5.5 V or +10.5 V VDD = 0 V or floating, VSS = −5.5 V ISS 0.1 μA typ Digital inputs = 0 V or 5.5 V 0.2 6 μA max VS = −5.5 V or +10.5 V 1 Guaranteed by design; not subject to production test. Rev. 0 | Page 4 of 24 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM PRODUCT HIGHLIGHTS TABLE OF CONTENTS SPECIFICATIONS 5 V DUAL SUPPLY 12 V SINGLE SUPPLY 5 V SINGLE SUPPLY CONTINUOUS CURRENT PER CHANNEL, SX OR DX POWER SUPPLY OPERATION ABSOLUTE MAXIMUM RATINGS THERMAL RESISTANCE ESD CAUTION PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS TERMINOLOGY THEORY OF OPERATION Normal Mode Isolation Mode Positive Fault Condition Negative Fault Condition; Negative Signal Handling APPLICATIONS INFORMATION Power Supply Sequencing OUTLINE DIMENSIONS ORDERING GUIDE