Datasheet ADG5412F-EP (Analog Devices) - 10

HerstellerAnalog Devices
BeschreibungFault Protection and Detection, 10 Ω RON, Quad SPST Switches
Seiten / Seite22 / 10 — ADG5412F-EP. Enhanced Product. −40°C to. −55°C to. Parameter. +25°C. …
RevisionB
Dateiformat / GrößePDF / 603 Kb
DokumentenspracheEnglisch

ADG5412F-EP. Enhanced Product. −40°C to. −55°C to. Parameter. +25°C. +85°C. +125°C. Unit. Test Conditions/Comments

ADG5412F-EP Enhanced Product −40°C to −55°C to Parameter +25°C +85°C +125°C Unit Test Conditions/Comments

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 21 link to page 21 link to page 21 link to page 20 link to page 20 link to page 20 link to page 21 link to page 21 link to page 21 link to page 19 link to page 19 link to page 19 link to page 19 link to page 19
ADG5412F-EP Enhanced Product −40°C to −55°C to Parameter +25°C +85°C +125°C Unit Test Conditions/Comments
DYNAMIC CHARACTERISTICS1 tON 400 ns typ RL = 300 Ω, CL = 35 pF 490 520 545 ns max VS = 18 V, see Figure 44 tOFF 375 ns typ RL = 300 Ω, CL = 35 pF 460 485 510 ns max VS = 18 V, see Figure 44 195 ns min VS1 = VS2 = 18 V, see Figure 44 Overvoltage Response Time, tRESPONSE 250 ns typ RL = 1 kΩ, CL = 2 pF, see Figure 39 350 360 375 ns max Overvoltage Recovery Time, tRECOVERY 1500 ns typ RL = 1 kΩ, CL = 2 pF, see Figure 40 2000 2300 2700 ns max Interrupt Flag Response Time, tDIGRESP 85 115 ns typ CL = 10 pF, see Figure 41 Interrupt Flag Recovery Time, tDIGREC 60 85 µs typ CL = 10 pF, see Figure 42 600 ns typ CL = 10 pF, RPULLUP = 1 kΩ, see Figure 43 Charge Injection, QINJ 610 pC typ VS = 18 V, RS = 0 Ω, CL = 1 nF, see Figure 45 Off Isolation −70 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz, see Figure 33 Channel-to-Channel Crosstalk −90 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz, see Figure 34 Total Harmonic Distortion Plus Noise, THD + N 0.001 % typ RL = 10 kΩ, VS = 18 V p-p, f = 20 Hz to 20 kHz, see Figure 38 −3 dB Bandwidth 270 MHz typ RL = 50 Ω, CL = 5 pF, see Figure 37 Insertion Loss −0.75 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz, see Figure 37 CS (Off) 12 pF typ VS = 18 V, f = 1 MHz CD (Off) 11 pF typ VS = 18 V, f = 1 MHz CD (On), CS (On) 23 pF typ VS = 18 V, f = 1 MHz POWER REQUIREMENTS VDD = 39.6 V, VSS = 0 V, digital inputs = 0 V, 5 V, or VDD Normal Mode IDD 0.9 mA typ 1.2 1.3 mA max IGND 0.4 mA typ 0.55 0.6 mA max ISS 0.5 mA typ 0.65 0.7 mA max Fault Mode VS = +55 V, −40 V IDD 1.2 mA typ 1.6 1.8 mA max IGND 0.8 mA typ 1.0 1.1 mA max ISS 0.5 mA typ 1.0 1.8 mA max VDD 8 V min GND = 0 V 44 V max GND = 0 V 1 Guaranteed by design; not subject to production test. Rev. B | Page 10 of 22 Document Outline FEATURES ENHANCED PRODUCT FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAM GENERAL DESCRIPTION PRODUCT HIGHLIGHTS REVISION HISTORY SPECIFICATIONS ±15 V DUAL SUPPLY ±20 V DUAL SUPPLY 12 V SINGLE SUPPLY 36 V SINGLE SUPPLY CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS OUTLINE DIMENSIONS ORDERING GUIDE