Datasheet SGP40 (Sensirion) - 6

HerstellerSensirion
BeschreibungIndoor Air Quality Sensor for VOC Measurements
Seiten / Seite19 / 6 — Condition. Parameter. Min. Max. Unit. Table 4. Figure 3. Figure 4. 2.4 …
Dateiformat / GrößePDF / 957 Kb
DokumentenspracheEnglisch

Condition. Parameter. Min. Max. Unit. Table 4. Figure 3. Figure 4. 2.4 Absolute Minimum and Maximum Ratings. Table 5

Condition Parameter Min Max Unit Table 4 Figure 3 Figure 4 2.4 Absolute Minimum and Maximum Ratings Table 5

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 7
Condition Parameter Min. Max. Unit
Operating conditions Relative humidity 0 90 % RH Temperature −10 50 °C Operating conditions of Humidity 1.5 (−13) 30 (+31) g m−3 (°C dew point) humidity compensation or – 90 % RH (the smaller) Temperature −10 50 °C Storage conditions Relative humidity 0 80 % RH Temperature 5 30 °C
Table 4
Recommended humidity and temperature conditions for storing and operating the SGP40. Dew point refers to maximum humidity allowed at minimum and maximum temperature, respectively.
Figure 3
Recommended relative humidity and temperature for
Figure 4
Recommended relative humidity and temperature for operating the SGP40. Green area marks conditions for which storing the SGP40. humidity compensation has been optimized. Additionally, gray areas mark operating conditions without considering the humidity compensation feature. To ensure an optimal performance of the SGP40, Handling and Assembly Instructions for SGPxx Gas Sensors as well as the Design-in Guide for Integrating SGP4x Gas Sensors need to be followed.
2.4 Absolute Minimum and Maximum Ratings
Stress levels beyond those listed in
Table 5
may cause permanent damage to the device. Exposure to minimum/maximum rating conditions for extended periods may affect sensor performance and reliability of the device. www.sensirion.com Version 1.1 – September 2021 6/19