Data SheetADG708/ADG709ABSOLUTE MAXIMUM RATINGS TA = 25°C, unless otherwise noted. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress Table 4. rating only; functional operation of the device at these or any ParameterRating other conditions above those indicated in the operational VDD to VSS 7 V section of this specification is not implied. Exposure to absolute VDD to GND −0.3 V to +7 V maximum rating conditions for extended periods may affect VSS to GND +0.3 V to −3.5 V device reliability. Analog Inputs1 VSS − 0.3 V to VDD + 0.3 V or 30 mA, whichever Only one absolute maximum rating can be applied at any one time. occurs first Digital Inputs1 −0.3 V to VDD + 0.3 V or 30 mA, whichever ESD CAUTION occurs first Peak Current, S or D (Pulsed at 1 ms, 100 mA 10% Duty Cycle Maximum) Continuous Current, S or D 30 mA Operating Temperature Industrial Temperature Range −40°C to +125°C Storage Temperature Range −65°C to +150°C Junction Temperature 150°C TSSOP Package, Power Dissipation 432 mW θJA Thermal Impedance 150.4°C/W θJC Thermal Impedance 27.6°C/W Lead Temperature, Soldering Vapor Phase (60 sec) 215°C Infrared (15 sec) 220°C 1 Overvoltages at A, EN, S, or D are clamped by internal codes. Current should be limited to the maximum ratings given. Rev. E | Page 9 of 20 Document Outline Features Applications General Description Functional Block Diagrams Product Highlights Table of Contents Revision History Specifications Dual Supply Absolute Maximum Ratings ESD Caution Pin Configurations and Function Descriptions Truth Tables Typical Performance Characteristics Test Circuits Terminology Applications Information Power Supply Sequencing Outline Dimensions Ordering Guide Automotive Products