Datasheet AOZ7270DI (Alpha & Omega) - 3

HerstellerAlpha & Omega
Beschreibung600V "Zero Bridge Loss" AlphaZBL Ideal Diode
Seiten / Seite17 / 3 — AOZ7270DI. Absolute Maximum Ratings. Recommend Operating Ratings. …
Dateiformat / GrößePDF / 1.1 Mb
DokumentenspracheEnglisch

AOZ7270DI. Absolute Maximum Ratings. Recommend Operating Ratings. Parameter. Rating. Note:. Electrical Characteristics. Bold. Symbol

AOZ7270DI Absolute Maximum Ratings Recommend Operating Ratings Parameter Rating Note: Electrical Characteristics Bold Symbol

Modelllinie für dieses Datenblatt

Textversion des Dokuments

AOZ7270DI Absolute Maximum Ratings Recommend Operating Ratings
Exceeding the Absolute Maximum ratings may damage the The device is not guaranteed to operate beyond the Maximum device. Operating Ratings.
Parameter Rating Parameter Rating
V Supply Voltage (V CCto Anode -0.3V to 24V IN) 16V Cathode to Anode -1V to 600V Ambient Temperature (TA) -40°C to 125°C Junction Temperature (TJ) 150°C Package Thermal Resistance 60°C/W Storage Temperature (TS) -65°C to 150°C 5x7 DFN-12 (JA) ESD Rating(1) 2kV Package Thermal Resistance 2.6°C/W 5x7 DFN-12 (
Note:
JC) 1. Devices are inherently ESD sensitive, handling precautions are required. Human body model rating: 1.5kΩ in series with 100pF.
Electrical Characteristics
TA = 25°C, Vcc = 16V, Vanode=0V, unless otherwise specified.Specifications in
Bold
indicate an ambient temperature range of -40°C to +125°C. These specifications are guaranteed by design.
Symbol Parameter Conditions Min. Typ. Max. Units
Repetitive peak reverse VRRM
600
V voltage Static cathode-anode RDS(ON) 0.19 Ω on-resistance Max. body-diode continuous IS 20 A current ISM Max. body-diode pulsed current 80 A VCC_UP Vcc UVLO rising Vca=-0.2V , Vcc rising monitor Ica >0.1A 13.5 15.2 17 V VCC_UVLO Vcc UVLO falling Vca=-0.2V , Vcc falling monitor Ica=0A 11 12.9 14 V ICharge Charging for Vcc Vca=30V ,Vcc=12V , measure Icathode 1 mA IOP Vcc operation current at on-state Vcc=16V , Vca=-0.1V , measure IVCC 12 µA Vcc quiescent current at IQ Vcc=16V , Vca=0.1V , measure I off-state VCC 5 µA VCA_ON Switch turn-on threshold Vcc=16V , Vca falling , monitor Ica> 0.1A -105 mV VCA_OFF Switch turn-off threshold Vcc=16V , Vca falling , monitor Ica = 0A 1 mV Rev. 1.0 September 2020
www.aosmd.com
Page 3 of 17