1.3 Absolute maximum ratings. 1/ Supply voltage (VDD) ... +7 V RF input power ... 25 dBm Continuous power dissipation (PD) : TCASE = +85C .. 0.82 W TCASE = +125C .. 0.46 W Storage temperature range (TSTG) .. -65C to +125C Peak reflow (moisture sensitivity level 1 (MSL1)) ... +260C Junction temperature (TJ) to maintain 1,000,000 hours mean time to failure (MTTF) ... +175C Nominal junction temperature (TA = +125C, VDD = 5 V, IDQ = 60 mA) .. +157.8C Thermal resistance, junction to case (JC) .. 109.3C/W Electrostatic discharge (ESD) rating: Human body model (HDM) per JEDEC JS-001 ... 500 V 1.4 Recommended operating conditions. 2/ Supply voltage (VDD) ... +5 V Operating temperature range (TA) ... -55C to +125C 1/ Stresses beyond those listed under “absolute maximum rating” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 2/ Use of this product beyond the manufacturers design rules or stated parameters is done at the user’s risk. The manufacturer and/or distributor maintain no responsibility or liability for product used beyond the stated limits. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/21602 REV PAGE 3