NJU7890PRELIMINARY SPECIFICATIONS SUBJECT TO CHANGE■ +HVIN input Voltage Range In order for this IC to operate normally, the positive input terminal voltage −HVIN (V+IN) of operational amplifier A must be within the common mode input voltage range of operational amplifier A. R1 Operational amplifier A: common mode input voltage range R2 V+ V- ≤ V −IN B +IN ≤ V+ -0.85V A Therefore, it is necessary to satisfy the following formula expressed by +IN V+/V− (supply voltage), V R2 +HVIN (+HVIN terminal voltage), VREF (REF R1 V− terminal voltage), ATT (attenuation rate). REF +HVIN Calculation ATT = R2/R1 1 1 V- ≤ × V+HVIN + × VREF ≤ V+ -0.85V 1 + ATT-1 1 + ATT Calculation example VREF = 4V, V+ / V− = 5V / 0V, ATT = 1/205 1 1 0V ≤ × V × 4V ≤ 5V -0.85V 1 + 205 +HVIN + 1 + 1⁄205 -820V ≤ V+HVIN ≤ 34.9V Characteristics example The figure below shows an example of characteristics when the attenuation rate is set to 1/205 (Aver) and 1/311 (Bver). The range indicated by the graph is the input voltage range of the +HVIN. +HVIN Input Voltage Range vs REF VoltageV+/V- = 5V/0V, VREF = 0 to 4.15V1400] 1200 ATT = 1/205 (Aver.) [V 1000 ATT = 1/311 (Bver.) eg800n a600e R400glta200o0t V-200-400InpuIN-600V H-800+ -1000-1200 -140000.511.522.533.544.5REF Voltage [V] Ver.0.0 - 6 - www.njr.com