Datasheet PVI5033RPbF (Infineon) - 2

HerstellerInfineon
BeschreibungPhotovoltaic Isolator Solid-State
Seiten / Seite5 / 2 — Series PVI5033RPbF. Electrical Specifications. INPUT CHARACTERISTICS. …
Revision01_00
Dateiformat / GrößePDF / 271 Kb
DokumentenspracheEnglisch

Series PVI5033RPbF. Electrical Specifications. INPUT CHARACTERISTICS. Limits. Units. OUTPUT CHARACTERISTICS

Series PVI5033RPbF Electrical Specifications INPUT CHARACTERISTICS Limits Units OUTPUT CHARACTERISTICS

Modelllinie für dieses Datenblatt

Textversion des Dokuments

Series PVI5033RPbF Electrical Specifications
(-40°C ≤ TA ≤ +85°C unless otherwise specified)
INPUT CHARACTERISTICS Limits Units
Min. Input Current (See Fig.1) 5.0 mA Input Current Range (See Fig. 1) 3.0 to 25 mA Max. Continuous Input Current @ TA=+25°C 40 mA LED Forward Voltage Drop @ 5mA, TA=+25°C (See Fig. 3) 1.4 V Max. Reverse Voltage 6.0 V Max. Reverse Current @ -6VDC, TA=+25°C 10 µA
OUTPUT CHARACTERISTICS Limits Units
Min. Forward Voltage 8.0 VDC Max. Reverse Current 10 µADC
COUPLED CHARACTERISTICS Limits Units
Min. Output Voltage @ ILED = 10mA, RL = 10MΩ 5 V @ TA=0°C to +70°C (See Fig. 1 & 2) Max. Output Voltage @ ILED = 10mA, RL = 10MΩ 10 V @ TA=0°C to +70°C (See Fig. 1 & 2) Max. Voltage Differential Between Outputs 1.0 V @ ILED = 5mA, RL = 10MΩ Min. Output Short-Circuit Current 1.65 µA @ ILED = 5mA, @ TA=+25°C (See Fig. 1 & 2) Typical Output Short-Circuit Current 5 µA @ ILED = 10mA, @ TA=+25°C (See Fig. 1 & 2) Max. Turn-On Time @ ILED = 5mA, CLOAD = 200pF (See Fig. 4) 2.5 ms Max. Turn-Off Time @ ILED = 5mA, CLOAD = 200pF (See Fig. 4) .5 ms Off-State Clamping Resistance: minimum 350 Ω maximum 1500 Ω
GENERAL CHARACTERISTICS Limits Units
Min. Dielectric Strength, Input-Output 3750 VRMS Min. Dielectric Strength, Output-to-Output 1200 VDC Min. Insulation Resistance, Input-to-Output 1012 Ω @TA=+25°C, 50%RH, 100VDC Max. Capacitance, Input-Output 5.0 pF Max. Pin Soldering Temperature (10 seconds max.) +260 °C Ambient Temperature Range: Operating -40 to +85 °C Storage -40 to +125 °C
Connection Diagram 1 8 (+)
International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support
2 7 (-)
applications. Users of this International Rectifier product in such applications assume all risks of such use and in- demnify International Rectifier against all damages re-
3 6 (+)
sulting from such use.
4 5 (-)
2 www.irf.com © 2015 International Rectifier Submit Datasheet Feedback April 24, 2015