Datasheet VCNL3030X01 (Vishay) - 2

HerstellerVishay
BeschreibungFully Integrated Proximity Sensor With Infrared Emitter, I2C Interface, and Interrupt Function
Seiten / Seite16 / 2 — VCNL3030X01. ORDERING INFORMATION ORDERING CODE. PACKAGING. VOLUME (1). …
Dateiformat / GrößePDF / 271 Kb
DokumentenspracheEnglisch

VCNL3030X01. ORDERING INFORMATION ORDERING CODE. PACKAGING. VOLUME (1). REMARKS. Note. SLAVE ADDRESS OPTIONS ORDERING CODE

VCNL3030X01 ORDERING INFORMATION ORDERING CODE PACKAGING VOLUME (1) REMARKS Note SLAVE ADDRESS OPTIONS ORDERING CODE

Modelllinie für dieses Datenblatt

Textversion des Dokuments

VCNL3030X01
www.vishay.com Vishay Semiconductors
ORDERING INFORMATION ORDERING CODE PACKAGING VOLUME (1) REMARKS
VCNL3030X01-GS08 MOQ: 3300 pcs Tape and reel 4.0 mm x 2.36 mm x 0.75 mm VCNL3030X01-GS18 MOQ: 13 000 pcs
Note
(1) MOQ: minimum order quantity
SLAVE ADDRESS OPTIONS ORDERING CODE SLAVE ADDRESS (7 bit)
VCNL3030X01-GS08 0x41 VCNL3030X01-GS18
ABSOLUTE MAXIMUM RATINGS
(Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. MAX. UNIT
Supply voltage VDD 2.5 3.6 V Operation temperature range Tamb -40 +105 °C Storage temperature range Tstg -40 +110 °C
RECOMMENDED OPERATING CONDITIONS
(Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL MIN. MAX. UNIT
Supply voltage VDD 2.5 3.6 V Operation temperature range Tamb -40 +105 °C I2C bus operating frequency f(I2CCLK) 10 400 kHz
PIN DESCRIPTIONS PIN ASSIGNMENT SYMBOL TYPE FUNCTION
1 VDD - Power supply input 2 SCL I I2C digital bus clock input 3 GND - Ground 4 IR ANODE I Anode for IRED 5 IR CATHODE I Cathode (IRED) connection 6 LDR I IRED driver input 7 INT O Interrupt pin 8 SDA I / O (open drain) I2C data bus data input / output Rev. 1.0, 12-Aug-2020
2