Datasheet VSC7428-02, VSC7429-02 (Microchip) - 738
Hersteller | Microchip |
Beschreibung | Caracal Family of Carrier Ethernet Switches |
Seiten / Seite | 758 / 738 — Pins. by. number. (continued). M24. VDD_AH_36. P11. VSS_75. R24. … |
Dateiformat / Größe | PDF / 5.0 Mb |
Dokumentensprache | Englisch |
Pins. by. number. (continued). M24. VDD_AH_36. P11. VSS_75. R24. Reserved_19. M25. P0_D1N. P12. VSS_76. R25. DDR_Rext. M26. P0_D1P. P13. VSS_77. R26. DDR_Vref. N1
Modelllinie für dieses Datenblatt
Textversion des Dokuments
Pins by number (continued) M24 VDD_AH_36 P11 VSS_75 R24 Reserved_19 M25 P0_D1N P12 VSS_76 R25 DDR_Rext M26 P0_D1P P13 VSS_77 R26 DDR_Vref N1 P11_D1P P14 VSS_78 T1 GPIO_27 N2 P11_D1N P15 VSS_79 T2 GPIO_26 N3 VSS_53 P16 VSS_80 T3 GPIO_25 N4 VSS_54 P17 VSS_81 T4 GPIO_24 N5 VSS_55 P18 VSS_82 T5 VDD_IO_9 N6 VDD_33 P19 VSS_83 T6 VDD_45 N7 VDD_34 P20 VDD_39 T7 VDD_46 N8 VSS_56 P21 VDD_40 T8 VSS_98 N9 VSS_57 P22 VDD_IODDR_1 T9 VSS_99 N10 VSS_58 P23 VSS_84 T10 VSS_100 N11 VSS_59 P24 VSS_85 T11 VSS_101 N12 VSS_60 P25 P0_D3N T12 VSS_102 N13 VSS_61 P26 P0_D3P T13 VSS_103 N14 VSS_62 R1 GPIO_31 T14 VSS_104 N15 VSS_63 R2 GPIO_30 T15 VSS_105 N16 VSS_64 R3 GPIO_29 T16 VSS_106 N17 VSS_65 R4 GPIO_28 T17 VSS_107 N18 VSS_66 R5 VDD_IO_8 T18 VSS_108 N19 VSS_67 R6 VDD_41 T19 VSS_109 N20 VDD_35 R7 VDD_42 T20 VDD_47 N21 VDD_36 R8 VSS_86 T21 VDD_48 N22 VSS_68 R9 VSS_87 T22 VDD_IODDR_3 N23 VSS_69 R10 VSS_88 T23 Reserved_21 N24 VSS_70 R11 VSS_89 T24 DDR_A13 N25 P0_D2N R12 VSS_90 T25 DDR_A12 N26 P0_D2P R13 VSS_91 T26 DDR_A11 P1 P11_D0P R14 VSS_92 U1 GPIO_23 P2 P11_D0N R15 VSS_93 U2 GPIO_22 P3 VSS_71 R16 VSS_94 U3 GPIO_21 P4 Reserved_24 R17 VSS_95 U4 GPIO_20 P5 VDD_IO_7 R18 VSS_96 U5 VDD_IO_10 P6 VDD_37 R19 VSS_97 U6 VSS_110 P7 VDD_38 R20 VDD_43 U7 VSS_111 P8 VSS_72 R21 VDD_44 U8 VSS_112 P9 VSS_73 R22 VDD_IODDR_2 U9 VSS_113 P10 VSS_74 R23 Reserved_20 U10 VSS_114 VSC7428-02 and VSC7429-02 Datasheet Revision 4.2 709 Document Outline 1 Revision History 1.1 Revision 4.2 1.2 Revision 4.1 1.3 Revision 4.0 1.4 Revision 2.0 2 Introduction 2.1 Register Notation 2.2 Standard References 2.3 Terms and Abbreviations 3 Product Overview 3.1 General Features 3.1.1 Layer-2 Switching 3.1.2 Multicast 3.1.3 Carrier Ethernet 3.1.4 Quality of Service 3.1.5 Security 3.1.6 Management 3.2 Applications 3.3 Related Products 3.4 Functional Overview 3.4.1 Frame Arrival 3.4.2 Basic and Advanced Frame Classification 3.4.3 VCAP-II Vitesse Content Aware Processor 3.4.4 Policing 3.4.5 Layer-2 Forwarding 3.4.6 Shared Queue System and Egress Scheduler 3.4.7 Rewriter and Frame Departure 3.4.8 CPU Port Module 3.4.9 Synchronous Ethernet and Precision Time Protocol 3.4.10 CPU System and Interfaces 4 Functional Descriptions 4.1 Port Modules 4.1.1 Port Module Numbering and Macro Connections 4.1.2 MAC 4.1.3 PCS 4.2 SERDES1G 4.2.1 SERDES1G Basic Configuration 4.2.2 SERDES1G Loopback Modes 4.2.3 Synchronous Ethernet 4.2.4 SERDES1G Deserializer Configuration 4.2.5 SERDES1G Serializer Configuration 4.2.6 SERDES1G Input Buffer Configuration 4.2.7 SERDES1G Output Buffer Configuration 4.2.8 SERDES1G Clock and Data Recovery (CDR) in 100BASE-FX 4.2.9 SERDES1G Energy Efficient Ethernet 4.2.10 SERDES1G Data Inversion 4.3 SERDES6G 4.3.1 SERDES6G Basic Configuration 4.3.2 SERDES6G Loopback Modes 4.3.3 Synchronous Ethernet 4.3.4 SERDES6G Deserializer Configuration 4.3.5 SERDES6G Serializer Configuration 4.3.6 SERDES6G Input Buffer Configuration 4.3.7 SERDES6G Output Buffer Configuration 4.3.8 SERDES6G Clock and Data Recovery (CDR) in 100BASE-FX 4.3.9 SERDES6G Energy Efficient Ethernet 4.3.10 SERDES6G Data Inversion 4.3.11 SERDES6G Signal Detection Enhancements 4.3.12 SERDES6G High-Speed I/O Configuration Bus 4.4 Copper Transceivers 4.4.1 Register Access 4.4.2 Cat5 Twisted Pair Media Interface 4.4.3 LED Interface 4.4.4 Ethernet Inline Powered Devices 4.4.5 IEEE 802.3af PoE Support 4.4.6 ActiPHY™ Power Management 4.4.7 Testing Features 4.4.8 VeriPHY™ Cable Diagnostics 4.5 Statistics 4.6 Classifier 4.6.1 General Data Extraction Setup 4.6.2 Frame Acceptance Filtering 4.6.3 QoS, DP, and DSCP Classification 4.6.4 VLAN Classification 4.6.5 Link Aggregation Code Generation 4.6.6 CPU Forwarding Determination 4.7 VCAP-II 4.7.1 Port Configuration 4.7.2 VCAP IS1 4.7.3 VCAP IS2 4.7.4 VCAP ES0 4.7.5 Range Checkers 4.7.6 VCAP-II Configuration 4.7.7 Advanced VCAP Operations 4.8 Analyzer 4.8.1 MAC Table 4.8.2 VLAN Table 4.8.3 Forwarding Engine 4.8.4 Analyzer Monitoring 4.9 Policers and Ingress Shapers 4.9.1 Policers 4.9.2 Ingress Shapers 4.10 Shared Queue System 4.10.1 Buffer Management 4.10.2 Frame Reference Management 4.10.3 Resource Depletion Condition 4.10.4 Configuration Example 4.10.5 Watermark Programming and Consumption Monitoring 4.10.6 Advanced Resource Management 4.10.7 Ingress Pause Request Generation 4.10.8 Tail Dropping 4.10.9 Test Utilities 4.10.10 Energy Efficient Ethernet 4.11 Scheduler and Shaper 4.11.1 Egress Shapers 4.11.2 Deficit Weighted Round Robin 4.11.3 Shaping and DWRR Scheduling Examples 4.12 Rewriter 4.12.1 VLAN Editing 4.12.2 DSCP Remarking 4.12.3 FCS Updating 4.12.4 CPU Extraction Header Insertion 4.13 CPU Port Module 4.13.1 Frame Extraction 4.13.2 Frame Injection 4.13.3 Network Processor Interface (NPI) 4.14 Layer-1 Timing 4.15 Hardware Timestamping 4.15.1 Timestamp Classification 4.15.2 One-Second Timer 4.15.3 Delay Timer 4.15.4 Time of Day Counter 4.16 Clocking and Reset 5 VCore-III System and CPU Interface 5.1 VCore-III Configurations 5.2 Clocking and Reset 5.2.1 Watchdog Timer 5.3 Shared Bus 5.3.1 Shared Bus Arbitration 5.3.2 SI Memory Region 5.3.3 PI Memory Region 5.3.4 DDR2 Memory Region 5.3.5 Switch Core Registers Memory Region 5.3.6 VCore-III Registers Memory Region 5.4 VCore-III CPU 5.4.1 Big Endian Support 5.4.2 Software Debug and Development 5.5 Manual Frame Injection and Extraction 5.5.1 Manual Frame Extraction 5.5.2 Manual Frame Injection 5.5.3 Frame Interrupts 5.6 Frame DMA 5.6.1 DMA Control Block Structures 5.6.2 Extraction 5.6.3 Injection 5.6.4 Frame DMA Interrupt 5.7 External CPU Support 5.7.1 Register Access and Multimaster Systems 5.7.2 Serial Interface in Slave Mode 5.7.3 Parallel Interface in Slave Mode 5.7.4 MIIM Interface in Slave Mode 5.7.5 Access to the VCore-III Shared Bus 5.7.6 Mailbox and Semaphores 5.8 VCore-III System Peripherals 5.8.1 Timers 5.8.2 UART 5.8.3 Two-Wire Serial Interface 5.8.4 MII Management Controller 5.8.5 GPIO Controller 5.8.6 Serial GPIO Controller 5.8.7 FAN Controller 5.8.8 Interrupt Controller 6 Features 6.1 Port Mapping 6.1.1 VSC7428 Port Mapping 6.1.2 VSC7429-02 Port Mapping 6.2 Switch Control 6.2.1 Switch Initialization 6.3 Port Module Control 6.3.1 MAC Configuration Port Mode Control 6.3.2 SerDes Configuration Port Mode Control 6.3.3 Port Reset Procedure 6.3.4 Port Counters 6.4 Layer-2 Switch 6.4.1 Basic Switching 6.4.2 Standard VLAN Operation 6.4.3 Provider Bridges and Q-in-Q Operation 6.4.4 Private VLANs 6.4.5 Asymmetric VLANs 6.4.6 Spanning Tree Protocols 6.4.7 IEEE 802.1X: Network Access Control 6.4.8 Link Aggregation 6.4.9 Simple Network Management Protocol (SNMP) 6.4.10 Mirroring 6.5 IGMP and MLD Snooping 6.5.1 IGMP and MLD Snooping Configuration 6.5.2 IP Multicast Forwarding Configuration 6.6 Quality of Service (QoS) 6.6.1 Basic QoS Configuration 6.6.2 IPv4 and IPv6 DSCP Remarking 6.6.3 Voice over IP (VoIP) 6.7 VCAP Applications 6.7.1 Notation for Control Lists Entries 6.7.2 Ingress Control Lists 6.7.3 Access Control Lists 6.7.4 Source IP Filter (SIP Filter) 6.7.5 DHCP Application 6.7.6 ARP Filtering 6.7.7 Ping Policing 6.7.8 TCP SYN Policing 6.8 CPU Extraction and Injection 6.8.1 Forwarding to CPU 6.8.2 Frame Extraction 6.8.3 Frame Injection 6.8.4 Frame Extraction and Injection Using An External CPU 6.9 Audio Video Bridging 6.10 Energy Efficient Ethernet 6.11 Carrier Ethernet Overview 6.11.1 Customer Bridge and Provider Bridge 6.11.2 MEF Services 6.11.3 MEF Bandwidth Profiles 6.11.4 MEF Service Attributes 6.11.5 Service Concept 6.11.6 Service Examples 6.11.7 Quality of Service Delivery 6.11.8 OAM and Protection Switching 6.11.9 Synchronous Ethernet Operation 6.11.10 IEEE 1588 Operation 7 Registers 7.1 Targets and Base Addresses 7.2 DEVCPU_ORG 7.2.1 DEVCPU_ORG:ORG 7.3 SYS 7.3.1 SYS:SYSTEM 7.3.2 SYS:SCH 7.3.3 SYS:SCH_LB 7.3.4 SYS:RES_CTRL 7.3.5 SYS:PAUSE_CFG 7.3.6 SYS:MMGT 7.3.7 SYS:MISC 7.3.8 SYS:STAT 7.3.9 SYS:PTP 7.3.10 SYS:POL 7.3.11 SYS:POL_MISC 7.3.12 SYS:ISHP 7.4 ANA 7.4.1 ANA:ANA 7.4.2 ANA:ANA_TABLES 7.4.3 ANA:PORT 7.4.4 ANA:COMMON 7.5 REW 7.5.1 REW:PORT 7.5.2 REW:COMMON 7.6 VCAP_CORE 7.6.1 VCAP_CORE:VCAP_CORE_CFG 7.6.2 VCAP_CORE:VCAP_CORE_CACHE 7.6.3 VCAP_CORE:VCAP_CORE_STICKY 7.6.4 VCAP_CORE:VCAP_CONST 7.6.5 VCAP_CORE:TCAM_BIST 7.7 VCAP_CORE 7.7.1 VCAP_CORE:VCAP_CORE_CFG 7.7.2 VCAP_CORE:VCAP_CORE_CACHE 7.7.3 VCAP_CORE:VCAP_CORE_STICKY 7.7.4 VCAP_CORE:VCAP_CONST 7.7.5 VCAP_CORE:TCAM_BIST 7.8 VCAP_CORE 7.8.1 VCAP_CORE:VCAP_CORE_CFG 7.8.2 VCAP_CORE:VCAP_CORE_CACHE 7.8.3 VCAP_CORE:VCAP_CORE_STICKY 7.8.4 VCAP_CORE:VCAP_CONST 7.8.5 VCAP_CORE:TCAM_BIST 7.9 DEVCPU_GCB 7.9.1 DEVCPU_GCB:CHIP_REGS 7.9.2 DEVCPU_GCB:SW_REGS 7.9.3 DEVCPU_GCB:VCORE_ACCESS 7.9.4 DEVCPU_GCB:GPIO 7.9.5 DEVCPU_GCB:DEVCPU_RST_REGS 7.9.6 DEVCPU_GCB:MIIM 7.9.7 DEVCPU_GCB:MIIM_READ_SCAN 7.9.8 DEVCPU_GCB:RAM_STAT 7.9.9 DEVCPU_GCB:MISC 7.9.10 DEVCPU_GCB:SIO_CTRL 7.9.11 DEVCPU_GCB:FAN_CFG 7.9.12 DEVCPU_GCB:FAN_STAT 7.9.13 DEVCPU_GCB:PTP_CFG 7.9.14 DEVCPU_GCB:PTP_STAT 7.9.15 DEVCPU_GCB:PTP_TIMERS 7.9.16 DEVCPU_GCB:MEMITGR 7.10 DEVCPU_QS 7.10.1 DEVCPU_QS:XTR 7.10.2 DEVCPU_QS:INJ 7.11 DEVCPU_PI 7.11.1 DEVCPU_PI:PI 7.12 HSIO 7.12.1 HSIO:PLL5G_CFG 7.12.2 HSIO:PLL5G_STATUS 7.12.3 HSIO:RCOMP_STATUS 7.12.4 HSIO:SYNC_ETH_CFG 7.12.5 HSIO:SERDES1G_ANA_CFG 7.12.6 HSIO:SERDES1G_DIG_CFG 7.12.7 HSIO:SERDES1G_DIG_STATUS 7.12.8 HSIO:MCB_SERDES1G_CFG 7.12.9 HSIO:SERDES6G_ANA_CFG 7.12.10 HSIO:SERDES6G_DIG_CFG 7.12.11 HSIO:MCB_SERDES6G_CFG 7.13 DEV_GMII 7.13.1 DEV_GMII:PORT_MODE 7.13.2 DEV_GMII:MAC_CFG_STATUS 7.14 DEV 7.14.1 DEV:DEV_CFG_STATUS 7.14.2 DEV:PORT_MODE 7.14.3 DEV:MAC_CFG_STATUS 7.14.4 DEV:PCS1G_CFG_STATUS 7.14.5 DEV:PCS1G_TSTPAT_CFG_STATUS 7.14.6 DEV:PCS_FX100_CONFIGURATION 7.14.7 DEV:PCS_FX100_STATUS 7.15 ICPU_CFG 7.15.1 ICPU_CFG:CPU_SYSTEM_CTRL 7.15.2 ICPU_CFG:PI_MST 7.15.3 ICPU_CFG:SPI_MST 7.15.4 ICPU_CFG:INTR 7.15.5 ICPU_CFG:GPDMA 7.15.6 ICPU_CFG:INJ_FRM_SPC 7.15.7 ICPU_CFG:TIMERS 7.15.8 ICPU_CFG:MEMCTRL 7.15.9 ICPU_CFG:TWI_DELAY 7.16 UART 7.16.1 UART:UART 7.17 TWI 7.17.1 TWI:TWI 7.18 SBA 7.18.1 SBA:SBA 7.19 GPDMA 7.19.1 GPDMA:CH 7.19.2 GPDMA:INTR 7.19.3 GPDMA:MISC 7.20 PHY 7.20.1 PHY:PHY_STD 7.20.2 PHY:PHY_EXT1 7.20.3 PHY:PHY_EXT2 7.20.4 PHY:PHY_GP 7.20.5 PHY:PHY_EEE 8 Electrical Specifications 8.1 DC Characteristics 8.1.1 Internal Pull-Up or Pull-Down Resistors 8.1.2 Reference Clock 8.1.3 DDR2 SDRAM Interface 8.1.4 SGMII DC Definitions and Test Circuits 8.1.5 Enhanced SerDes Interface 8.1.6 SerDes (SGMII) Interface 8.1.7 MIIM, GPIO, SI, JTAG, and Miscellaneous Signals 8.1.8 Thermal Diode 8.2 AC Characteristics 8.2.1 Reference Clock 8.2.2 Reset Timing 8.2.3 DDR2 SDRAM Signal 8.2.4 Enhanced SerDes Interface 8.2.5 SerDes (SGMII) Interface 8.2.6 MII Management 8.2.7 Serial CPU Interface (SI) Master Mode 8.2.8 Serial CPU Interface (SI) for Slave Mode 8.2.9 Parallel Interface (PI) Master Mode 8.2.10 Parallel Interface (PI) Slave Mode 8.2.11 JTAG Interface 8.2.12 Serial Inputs/Outputs 8.2.13 Recovered Clock Outputs 8.2.14 Two-Wire Serial Interface 8.2.15 IEEE 1588 Time Tick Output 8.3 Current and Power Consumption 8.3.1 Current Consumption 8.3.2 Power Consumption 8.3.3 Power Supply Sequencing 8.4 Operating Conditions 8.5 Stress Ratings 9 Pin Descriptions for VSC7428-02 9.1 Pin Diagram for VSC7428-02 9.2 Pins by Function for VSC7428-02 9.2.1 Analog Bias Signals 9.2.2 Clock Circuits 9.2.3 DDR2 SDRAM Interface 9.2.4 General-Purpose Inputs and Outputs 9.2.5 JTAG Interface 9.2.6 MII Management Interface 9.2.7 Miscellaneous Signals 9.2.8 Parallel Interface 9.2.9 Power Supplies and Ground 9.2.10 Serial CPU Interface 9.2.11 SerDes Interface 9.2.12 Enhanced SerDes Interface 9.2.13 Twisted Pair Interface 9.3 Pins by Number for VSC7428-02 9.4 Pins by Name for VSC7428-02 10 Pin Descriptions for VSC7429-02 10.1 Pin Diagram for VSC7429-02 10.1.1 Pins by Function for VSC7429-02 10.2 Pins by Number for VSC7429-02 10.3 Pins by Name for VSC7429-02 11 Package Information 11.1 Package Drawing 11.2 Thermal Specifications 11.3 Moisture Sensitivity 12 Design Guidelines 12.1 Power Supplies 12.2 Power Supply Decoupling 12.3 Reference Clock 12.3.1 Single-Ended RefClk Input 12.4 Interfaces 12.4.1 General Recommendations 12.4.2 SGMII Interface 12.4.3 Parallel Interface 12.4.4 Serial Interface 12.4.5 Enhanced SerDes Interface 12.4.6 Two-Wire Serial Interface 12.4.7 DDR2 SDRAM Interface 12.4.8 Thermal Diode External Connection 13 Design Considerations 13.1 10BASE-T mode unable to re-establish link 13.2 Software script for link performance 13.3 10BASE-T signal amplitude 13.4 Clause 45 register 7.60 13.5 Clause 45 register 3.22 13.6 Clause 45 register 3.1 13.7 Clause 45 register address post-increment 13.8 IEEE1588 Out of Sync Situation 13.8.1 Copper Port (internal CuPHY 10-11 and External PHYs Without Timestamping) 13.8.2 Serdes Port (SFP) 14 Ordering Information