Datasheet ADT75 (Analog Devices) - 8

HerstellerAnalog Devices
Beschreibung±1°C Accurate, 12-Bit Digital Temperature Sensor
Seiten / Seite24 / 8 — ADT75. Data Sheet. PIN CONFIGURATION AND FUNCTION DESCRIPTIONS. SDA. VDD. …
RevisionB
Dateiformat / GrößePDF / 353 Kb
DokumentenspracheEnglisch

ADT75. Data Sheet. PIN CONFIGURATION AND FUNCTION DESCRIPTIONS. SDA. VDD. SCL. TOP VIEW. OS/ALERT. (Not to Scale). GND

ADT75 Data Sheet PIN CONFIGURATION AND FUNCTION DESCRIPTIONS SDA VDD SCL TOP VIEW OS/ALERT (Not to Scale) GND

Modelllinie für dieses Datenblatt

Textversion des Dokuments

ADT75 Data Sheet PIN CONFIGURATION AND FUNCTION DESCRIPTIONS SDA 1 8 VDD SCL ADT75 2 7 A0 TOP VIEW OS/ALERT 3 6 A1 (Not to Scale) GND 4 5 A2
05326-004 Figure 4. Pin Configuration
Table 5. Pin Function Descriptions Pin No. Mnemonic Description
1 SDA SMBus/I2C Serial Data Input/Output. Serial data that is loaded into and read from the ADT75 registers is provided on this pin. Open-drain configuration; needs a pull-up resistor. 2 SCL Serial Clock Input. This is the clock input for the serial port. The serial clock is used to clock in and clock out data to and from any register of the ADT75. Open-drain configuration; needs a pull-up resistor. 3 OS/ALERT Over- and Undertemperature Indicator. Default power as an OS pin. Open-drain configuration; needs a pull-up resistor. 4 GND Analog and Digital Ground. 5 A2 SMBus/I2C Serial Bus Address Selection Pin. Logic input. Can be set to GND or V . DD 6 A1 SMBus/I2C Serial Bus Address Selection Pin. Logic input. Can be set to GND or V . DD 7 A0 SMBus/I2C Serial Bus Address Selection Pin. Logic input. Can be set to GND or V . DD 8 V Positive Supply Voltage, 2.7 V to 5.5 V. Decouple the supply to ground. DD Rev. B | Page 8 of 24 Document Outline Features Applications Product Highlights Functional Block Diagram Table of Contents Revision History General Description Specifications A Grade B Grade Timing Specifications and Diagram Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Theory of Operation Circuit Information Converter Details Functional Description Temperature Data Format Temperature Conversion Formulas One-Shot Mode Fault Queue Registers Address Pointer Register Temperature Value Register Configuration Register THYST Setpoint Register TOS Setpoint Register Serial Interface Serial Bus Address Writing Data Writing to the Address Pointer Register for a Subsequent Read Writing Data to a Register Reading Data OS/Alert Output OverTemperature Modes Comparator Mode Interrupt Mode SMBus Alert Applications Information Thermal Response Time Self-Heating Effects Supply Decoupling Temperature Monitoring Outline Dimensions Ordering Guide