Type PPC, -55 ºC to + 125 ºC, Ultra-Thin Polymer Aluminum Electrolytic Capacitor Derated DC Life Test at 105°C at 20 Vdc Hours 0 500 1000 2000 3000 4000 5000 6000 7000 8000 90000 10000 0.00% This graph represents 8 units on test for -2.00% ge 10,000 hours -4.00% -6.00% ce Chan -8.00% itan ac -10.00% Cap -12.00% -14.00% Charge/Discharge Test Data 0.1 Hz, 0.22Ω, @ 16Vdc @ 25C 0.00% This graph represents ge -1.00% 4 units on test for -2.00% 100,000 cycles -3.00% -4.00% ce Chan -5.00% itan -6.00% ac -7.00% Cap 0 10000 20000 55000 100000 Charge/Discharge Cycles Charge/Discharge Test Data 0.1 Hz, 0.22Ω, @ 16Vdc @ 25C This graph represents 0.0048 4 units on test for 100,000 cycles 0.0047 Ω 0.0046 ESR 0.0045 0.0044 0 10,000 20,000 55,000 100,000 Charge/Discharge Cycles CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800