Datasheet XDPS21071 (Infineon) - 10

HerstellerInfineon
BeschreibungForced Frequency Resonant Flyback controller
Seiten / Seite54 / 10 — Forced Frequency Resonant Flyback controller. Functional Description. BM …
Revision01_00
Dateiformat / GrößePDF / 2.2 Mb
DokumentenspracheEnglisch

Forced Frequency Resonant Flyback controller. Functional Description. BM 2-point. Power. BM Ctrl. Regulation. Management

Forced Frequency Resonant Flyback controller Functional Description BM 2-point Power BM Ctrl Regulation Management

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 10 link to page 10 link to page 11 link to page 11
Forced Frequency Resonant Flyback controller Functional Description
MFIO C5 burst-on VMFIOBMWK
BM 2-point Power BM Ctrl Regulation Management
C6 burst-off V MFIOBMPA
Figure 6 Burst mode control
For the system dimensioning, it should be ensured that the voltage VVCC should be always well above the threshold V VCCoff, including the burst-off phase. Figure 7 shows a typical burst mode operation signal for VCC and correlated current consumption. V VCC(t) burst-on phase VVCCSS VVCCoff = 7.2 V t V burst-off phase MFIO(t) VMFIOBMWK = 1.6 V VMFIOBMPA t VGD0(t) t IVCC(t) IVCCop IVCCquBM2 = 460 µA t
Figure 7 Burst operation 4.1.5 Bang-bang mode during latched and auto-restart operation
The bang-bang mode supports an IC operation without external VCC supply during the latched and auto-restart operation. It directly controls the HV startup cell depending on the set bang-bang mode turn-on threshold VVCCBBon of the corresponding auto-restart and latch mode (see Figure 8). In latch mode, the HV startup cell switch-on threshold is set to VVCCBBon = 9 V (see Chapter 4.1.5.1 and Chapter 4.1.5.2). In auto-restart mode, there is also an additional stand-by timer active that switches on the HV startup cell in a fixed time period of 500ms scheme to keep the VCC all the time at a high level above the brown-in threshold VVCCBI = 9.1 V. Then a restart can take place without going through an additional VCC brown-in cycle. Due to the low current consumption during the auto-restart break time, the startup cell is always turned on by the 500 ms timer.
Protection Modes
HV
HV Startup-cell Auto Restart
Closed/Open
Bang-Bang Ctrl Startup-Cell Mode
VVCCBBoff = 20.5 V
Driver
V
Latch
VCCBBonAR/LM = 9 V
Mode
D1
Power
VCC
Management Figure 8 Bang-bang mode control of HV startup-cell
Data Sheet 10 Revision 2.0 2019-10-30