Datasheet HS1101LF (TE Connectivity) - 3

HerstellerTE Connectivity
BeschreibungRelative Humidity Sensor
Seiten / Seite6 / 3 — BLOCK DIAGRAM. CIRCUIT. Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ …
Dateiformat / GrößePDF / 219 Kb
DokumentenspracheEnglisch

BLOCK DIAGRAM. CIRCUIT. Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF

BLOCK DIAGRAM CIRCUIT Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF

Modelllinie für dieses Datenblatt

Textversion des Dokuments

HS1101LF Relative Humidity Sensor MEASUREMENT FREQUENCY INFLUENCE In this data sheet, all capacitance measurements are done @ 10 kHz / 1Volt. However, the sensor can operate without restriction from 5 kHz to 300 kHz POLARISATION In order to get a better reproducibility during measurements, always connect the case of the header (pin 2) to the ground of the circuit. The case of the header is located on the opposite side of the tab. SOLDERING INSTRUCTIONS We recommend taking specific attention to soldering conditions to get the best performance of MEAS-France sensors. See Application Note. To get it, please contact: humidity.application@te.com. PROPORTIONAL VOLTAGE OUTPUT CIRCUIT
BLOCK DIAGRAM
FREQUENCY OUTPUT CIRCUIT
CIRCUIT Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF
SENSOR SOLUTIONS /// HS1101LF HPC052_J 9/2015 Page 3 Document Outline HS1101LF Relative Humidity Sensor