link to page 6 Enhanced ProductADuM3221-EPABSOLUTE MAXIMUM RATINGS Ambient temperature = 25°C, unless otherwise noted. Table 8.Table 9. Maximum Continuous Working Voltage1ParameterRatingParameterMaxUnitConstraint Storage Temperature (T ) −55°C to +150°C AC Bipolar Voltage 565 V peak 50-year minimum lifetime ST Operating Temperature (T ) −55°C to +150°C AC Unipolar Voltage 1131 V peak 50-year minimum lifetime J Supply Voltage Ranges1 DC Voltage 1131 V peak 50-year minimum lifetime V −0.5 V to +7.0 V 1 DD1 Refers to the continuous voltage magnitude imposed across the isolation V −0.5 V to +20 V barrier. DD2 Input Voltage Range (V , V )1, 2 −0.5 V to V + 0.5 V IA IB DDI Output Voltage Range (V , V )1, 2 −0.5 V to V + 0.5 V ESD CAUTION OA OB DDO Average Output Current per Pin (I )3 −23 mA to +23 mA O Common-Mode Transients, −100 kV/µs to +100 kV/µs (CM , CM )4 H L 1 All voltages are relative to their respective ground. 2 V DDI and VDDO refer to the supply voltages on the input and output sides of a given channel, respectively. 3 See Figure 2 for information about maximum allowable current for various temperatures. 4 Refers to common-mode transients across the insulation barrier. Common- mode transients exceeding the Absolute Maximum Rating can cause latch-up or permanent damage. Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a stress rating only; functional operation of the product at these or any other conditions above those indicated in the operational section of this specification is not implied. Operation beyond the maximum operating conditions for extended periods may affect product reliability. Rev. 0 | Page 7 of 12 Document Outline FEATURES ENHANCED PRODUCT FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V OPERATION ELECTRICAL CHARACTERISTICS—3.3 V OPERATION PACKAGE CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY RELATED SPECIFICATIONS DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS RECOMMENDED OPERATING CONDITIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS OUTLINE DIMENSIONS ORDERING GUIDE