link to page 6 link to page 6 ADuM3223/ADuM4223Data SheetREGULATORY INFORMATION The ADuM3223 is approved or pending approval by the organizations listed in Table 6. Table 6. ULCSAVDE Recognized under UL 1577 Approved under CSA Component Acceptance Notice 5A Certified according to DIN V VDE V 0884-10 Component Recognition (VDE V 0884-10): 2006-122 Program1 Single/Protection 3000 V rms Basic insulation per CSA 60950-1-07 and IEC 60950-1, Reinforced insulation, 560 V peak Isolation Voltage 380 V rms (537 V peak) maximum working voltage File E214100 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM3223 is proof tested by applying an insulation test voltage ≥ 3600 V rms for 1 second (current leakage detection limit = 6 µA). 2 In accordance with DIN V VDE V 0884-10, each ADuM3223 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval. The ADuM4223 is approved or pending approval by the organizations listed in Table 7. Table 7. ULCSACQCVDE Recognized Under Approved under CSA Component Approved under CQC11-471543-2012 Certified according to UL 1577 Component Acceptance Notice 5A DIN V VDE V 0884-10 Recognition Program1 (VDE V 0884-10): 2006- 122 Single/Protection Reinforced insulation per Reinforced insulation per GB4943.1-2011, Reinforced insulation, 5000 V rms Isolation CSA 60950-1-07 and IEC 60950-1, 380 V rms (537 V peak) maximum working 849 V peak Voltage 380 V rms (537 V peak) maximum voltage, tropical climate, altitude ≤ 5000 m; working voltage; basic insulation basic insulation per GB4943.1-2011, per CSA 60950-1-07 and IEC 60950-1, 600 V rms (848 V peak) maximum working 760 V rms (1074 V peak) maximum voltage, tropical climate, altitude ≤ 5000 m working voltage File E214100 File 205078 File CQC14001108627 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM4223 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 µA). 2 In accordance with DIN V VDE V 0884-10, each ADuM4223 is proof tested by applying an insulation test voltage ≥ 1592 V peak for 1 second (partial discharge detection limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval. Rev. J | Page 6 of 20 Document Outline Features Applications Functional Block Diagram General Description Revision History Specifications Electrical Characteristics—5 V Operation Electrical Characteristics—3.3 V Operation Package Characteristics Insulation and Safety-Related Specifications ADuM3223 ADuM4223 Regulatory Information DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Applications Information PC Board Layout Propagation Delay-Related Parameters Thermal Limitations and Switch Load Characteristics Output Load Characteristics Boot-Strapped Half-Bridge Operation DC Correctness and Magnetic Field Immunity Power Consumption Insulation Lifetime Outline Dimensions Ordering Guide Automotive Products