Hall-Effect Linear Current Sensor withACS711Overcurrent Fault Output for < 100 V Isolation ApplicationsCharacteristic Performance Data Data taken using the ACS711KLC-12A, VCC = 3.3 V Accuracy DataElectrical Offset Voltage versus Ambient TemperatureSensitivity versus Ambient Temperature80114601134011220111(mV)0110V OESens (mV/A)-20109-40108-60107–60–40–20020406080100120140–60–40–20020406080100120140TA (°C)TA (°C)Nonlinearity versus Ambient TemperatureSymmetry versus Ambient Temperature2.0101.51.5101.01.0100.50.5(%)(%) 100.0E LIN0E SYM-0.599.5-1.099.0-1.598.5–60–40–20020406080100120140–60–40–20020406080100120140TA (°C)TA (°C)Total Output Error versus Ambient TemperatureFault Operating Point versus Ambient Temperature816614412 102(%)(A)8TT0E TOI FAUL6-24-42-60–60–40–20020406080100120140–60–40–20020406080100120140TA (°C)TA (°C) Typical Maximum Limit Mean Typical Minimum Limit Allegro MicroSystems, LLC 10 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com