Datasheet LTC3736-2 (Analog Devices) - 3

HerstellerAnalog Devices
BeschreibungDual 2-Phase, No RSENSE , Synchronous Controller with Output Tracking
Seiten / Seite28 / 3 — ELECTRICAL CHARACTERISTICS. The. denotes the specifi cations which apply …
Dateiformat / GrößePDF / 357 Kb
DokumentenspracheEnglisch

ELECTRICAL CHARACTERISTICS. The. denotes the specifi cations which apply over the full operating

ELECTRICAL CHARACTERISTICS The denotes the specifi cations which apply over the full operating

Modelllinie für dieses Datenblatt

Textversion des Dokuments

LTC3736-2
ELECTRICAL CHARACTERISTICS The
l
denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. VIN = 4.2V unless otherwise specifi ed. PARAMETER CONDITIONS MIN TYP MAX UNITS Main Control Loops
Input DC Supply Current (Note 4) Normal Mode RUN/SS = VIN 4.75 750 μA Shutdown RUN/SS = 0V 9 20 μA UVLO VIN = UVLO Threshold –200mV 3 10 μA Undervoltage Lockout Threshold VIN Falling l 1.95 2.25 2.55 V VIN Rising l 2.15 2.45 2.75 V Shutdown Threshold at RUN/SS 0.45 0.65 0.85 V Start-Up Current Source RUN/SS = 0V 0.4 0.7 1 μA Regulated Feedback Voltage 0°C to 85°C (Note 5) 0.594 0.6 0.606 V –40°C to 85°C l 0.591 0.6 0.609 V Output Voltage Line Regulation 2.75V < VIN < 9.8V (Note 5) 0.05 0.2 mV/ V Output Voltage Load Regulation ITH = 0.9V (Note 5) 0.12 0.5 % ITH = 1.7V –0.12 –0.5 % VFB1,2 Input Current (Note 5) 10 50 nA TRACK Input Current TRACK = 0.6V 10 50 nA Overvoltage Protect Threshold Measured at VFB 0.66 0.68 0.7 V Overvoltage Protect Hysteresis 20 mV Auxiliary Feedback Threshold SYNC/FCB Ramping Positive 0.525 0.6 0.675 V Top Gate (TG) Drive 1, 2 Rise Time CL = 3000pF 40 ns Top Gate (TG) Drive 1, 2 Fall Time CL = 3000pF 40 ns Bottom Gate (BG) Drive 1, 2 Rise Time CL = 3000pF 50 ns Bottom Gate (BG) Drive 1, 2 Fall Time CL = 3000pF 40 ns Maximum Current Sense Voltage (ΔVSENSE(MAX)) IPRG = Floating l 220 240 260 mV (SENSE+ – SW) IPRG = 0V l 150 167 185 mV IPRG = VIN l 320 345 370 mV Soft-Start Time Time for VFB1 to Ramp from 0.05V to 0.55V 0.667 0.833 1 ms
Oscillator and Phase-Locked Loop
Oscillator Frequency Unsynchronized (SYNC/FCB Not Clocked) PLLLPF = Floating 480 550 600 kHz PLLLPF = 0V 260 300 340 kHz PLLLPF = VIN 650 750 825 kHz Phase-Locked Loop Lock Range SYNC/FCB Clocked Minimum Synchronizable Frequency l 200 250 kHz Maximum Synchronizable Frequency l 850 1150 kHz Phase Detector Output Current Sinking fOSC > fSYNC/FCB –4 μA Sourcing fOSC < fSYNC/FCB 4 μA
PGOOD Output