ELECTRICAL CHARACTERISTICS. The. denotes the specifi cations which apply over the full operating

ELECTRICAL CHARACTERISTICS The denotes the specifi cations which apply over the full operating

Modelllinie für dieses Datenblatt

Textversion des Dokuments

LTC3826
ELECTRICAL CHARACTERISTICS The
l
denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C. VIN = 12V, VRUN/SS1, 2 = 5V unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
IPLLLPF Phase Detector Output Current Sinking Capability fPLLIN/MODE < fOSC –5 μA Sourcing Capability fPLLIN/MODE > fOSC 5 μA
PGOOD Output
VPGL PGOOD Voltage Low IPGOOD = 2mA 0.1 0.3 V IPGOOD PGOOD Leakage Current VPGOOD = 5V ±1 μA VPG PGOOD Trip Level VFB with Respect to Set Regulated Voltage VFB Ramping Negative –12 –10 –8 % VFB Ramping Positive 8 10 12 %
Note 1:
Stresses beyond those listed under Absolute Maximum Ratings
Note 4:
The LTC3826 is tested in a feedback loop that servos VITH1, 2 to a may cause permanent damage to the device. Exposure to any Absolute specifi ed voltage and measures the resultant VFB1, 2. Maximum Rating condition for extended periods may affect device
Note 5:
Dynamic supply current is higher due to the gate charge being reliability and lifetime. delivered at the switching frequency. See Applications Information.
Note 2:
The LTC3826E is guaranteed to meet performance specifi cations
Note 6:
Rise and fall times are measured using 10% and 90% levels. Delay from 0°C to 85°C. Specifi cations over the –40°C to 85°C operating times are measured using 50% levels. temperature range are assured by design, characterization and correlation
Note 7:
The minimum on-time condition is specifi ed for an inductor with statistical process controls. The LTC3826I is guaranteed to meet peak-to-peak ripple current ≥40% of IMAX (see minimum on-time performance specifi cations over the full –40°C to 85°C operating considerations in the Applications Information section). temperature range.
Note 3:
TJ is calculated from the ambient temperature TA and power dissipation PD according to the following formulas: TJ = TA + (PD • 34 °C/W) 3826fc 4