LT1800 ELECTRICAL CHARACTERISTICSNote 1: Stresses beyond those listed under Absolute Maximum Ratings Note 4: The LT1800C/LT1800I are guaranteed functional over the may cause permanent damage to the device. Exposure to any Absolute temperature range of –40°C to 85°C. Maximum Rating condition for extended periods may affect device Note 5: The LT1800C is guaranteed to meet specifi ed performance from reliability and lifetime. 0°C to 70°C. The LT1800C is designed, characterized and expected to Note 2: The inputs are protected by back-to-back diodes and by ESD meet specifi ed performance from –40°C to 85°C but is not tested or diodes to the supply rails. If the differential input voltage exceeds 1.4V or QA sampled at these temperatures. The LT1800I is guaranteed to meet either input goes outside the rails, the input current should be limited to specifi ed performance from –40°C to 85°C. less than 10mA. Note 6: Minimum supply voltage is guaranteed by power supply rejection Note 3: A heat sink may be required to keep the junction temperature ratio test. below the absolute maximum rating when the output is shorted Note 7: Output voltage swings are measured between the output and indefi nitely. power supply rails. Note 8: This parameter is not 100% tested. TYPICAL PERFORMANCE CHARACTERISTICSVOS Distribution, VCM = 0VVOS Distribution, VCM = 5VVOS Distribution, VCM = 0V(SO-8, PNP Stage)(SO-8, NPN Stage)(SOT-23, PNP Stage) 45 45 40 VS = 5V, 0V VS = 5V, 0V VS = 5V, 0V 40 VCM = 0V 40 VCM = 5V 35 VCM = 0V 35 35 30 30 30 25 25 25 20 20 20 15 15 15 PERCENT OF UNITS (%) PERCENT OF UNITS (%) PERCENT OF UNITS (%) 10 10 10 5 5 5 0 0 0 –250 –150 –50 50 150 250 –2000 –1200 –400 400 1200 2000 –1250 –750 –250 250 750 1250 INPUT OFFSET VOLTAGE (μV) INPUT OFFSET VOLTAGE (μV) INPUT OFFSET VOLTAGE (μV) 1800 G01 1800 G02 1800 G03 VOS Distribution, VCM = 5VOffset Voltage(SOT-23, NPN Stage)Supply Current vs Supply Voltagevs Input Common Mode Voltage 35 4 500 VS = 5V, 0V VS = 5V, 0V V 400 TA = –55°C TYPICAL PART 30 CM = 5V 300 3 T 25 A = 125°C 200 T 100 A = 25°C 20 T 2 A = 25°C 0 15 –100 TA = –55°C 10 –200 PERCENT OF UNITS (%) SUPPLY CURRENT (mA) OFFSET VOLTAGE (μV) 1 T –300 A = 125°C 5 –400 0 0 –500 –2500 –1500 –500 500 1500 2500 0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 INPUT OFFSET VOLTAGE (μV) TOTAL SUPPLY VOLTAGE (V) INPUT COMMON MODE VOLTAGE (V) 1800 G04 1800 G05 1800 G06 1800fa 7