ADuM6000. Data Sheet. ABSOLUTE MAXIMUM RATINGS. Table 10. Parameter. Rating. ESD CAUTION

ADuM6000 Data Sheet ABSOLUTE MAXIMUM RATINGS Table 10 Parameter Rating ESD CAUTION

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 12 link to page 6 link to page 15 link to page 8 link to page 8 link to page 8 link to page 8 link to page 8 link to page 8
ADuM6000 Data Sheet ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress
Table 10.
rating only; functional operation of the device at these or any
Parameter Rating
other conditions above those indicated in the operational Storage Temperature (TST) −55°C to +150°C section of this specification is not implied. Exposure to absolute Ambient Operating Temperature (TA) −40°C to +105°C maximum rating conditions for extended periods may affect Supply Voltages (VDD1, VISO)1 −0.5 V to +7.0 V device reliability. Input Voltage (RCIN, RCSEL)1, 2 −0.5 V to VDDI + 0.5 V Output Voltage (RCOUT)1, 2 −0.5 V to VDDO + 0.5 V Average Total Output Current (I
ESD CAUTION
ISO)3 80 mA Common-Mode Transients4 −100 kV/µs to +100 kV/µs 1 Each voltage is relative to its respective ground. 2 VDDI and VDDO refer to the supply voltages on the input and output sides of a given channel, respectively. See the PCB Layout section. 3 See Figure 2 for maximum rated current values for various temperatures. 4 Refers to common-mode transients across the isolation barrier. Common- mode transients exceeding the absolute maximum ratings may cause latch-up or permanent damage.
Table 11. Maximum Continuous Working Voltage1 Parameter Max Unit Applicable Certification
AC Voltage, Bipolar Waveform 424 V peak All certifications, 50-year operation AC Voltage, Unipolar Waveform Basic Insulation 600 V peak Reinforced Insulation 565 V peak Working voltage per IEC 60950-1 DC Voltage Basic Insulation 600 V peak Reinforced Insulation 565 V peak Working voltage per IEC 60950-1 1 Refers to the continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more information. Rev. D | Page 8 of 16 Document Outline Features Applications General Description Functional Block Diagram Revision History Specifications Electrical Characteristics—5 V Primary Input Supply/5 V Secondary Isolated Supply Electrical Characteristics—3.3 V Primary Input Supply/3.3 V Secondary Isolated Supply Electrical Characteristics—5 V Primary Input Supply/3.3 V Secondary Isolated Supply Package Characteristics Regulatory Information Insulation and Safety-Related Specifications DIN V VDE V 0884-10 (VDE V 0884-10) and IEC 60747-5-2 (VDE 0884 Part 2):2003-01 Insulation Characteristics Thermal Derating Curve Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Applications Information PCB Layout Start-Up Behavior EMI Considerations Thermal Analysis Current Limit and Thermal Overload Protection Power Considerations Increasing Available Power Insulation Lifetime Outline Dimensions Ordering Guide