Datasheet RH1085 (Analog Devices) - 4

HerstellerAnalog Devices
Beschreibung3A Low Dropout Positive Adjustable Regulator
Seiten / Seite6 / 4 — TABLE 2: ELECTRICAL TEST REQUIREMENTS. MIL-STD-883 TEST REQUIREMENTS. …
Dateiformat / GrößePDF / 80 Kb
DokumentenspracheEnglisch

TABLE 2: ELECTRICAL TEST REQUIREMENTS. MIL-STD-883 TEST REQUIREMENTS. SUBGROUP. PDA Test Notes. TOTAL DOSE BIAS CIRCUIT

TABLE 2: ELECTRICAL TEST REQUIREMENTS MIL-STD-883 TEST REQUIREMENTS SUBGROUP PDA Test Notes TOTAL DOSE BIAS CIRCUIT

Modelllinie für dieses Datenblatt

Textversion des Dokuments

RH1085
TABLE 2: ELECTRICAL TEST REQUIREMENTS MIL-STD-883 TEST REQUIREMENTS SUBGROUP PDA Test Notes
The PDA is specified as 5% based on failures from group A, subgroup 1, Final Electrical Test Requirements (Method 5004) 1*,2,3,4,5,6 tests after cooldown as the final electrical test in accordance with method Group A Test Requirements (Method 5005) 1,2,3,4,5,6 5004 of MIL-STD-883 Class B. The verified failures of group A, subgroup 1, Group C and D End Point Electrical Parameters 1 after burn-in divided by the total number of devices submitted for burn-in (Method 5005) in that lot shall be used to determine the percent for the lot. Linear Technology Corporation reserves the right to test to tighter limits *PDA applies to subgroup 1. See PDA Test Notes. than those given.
TOTAL DOSE BIAS CIRCUIT
15V RH1085 VOUT ADJ 150Ω –15V RH1085 BC
TYPICAL PERFORMANCE CHARACTERISTICS Reference Voltage Ripple Rejection Current Limit
1.26 105 0.46 10mA ≤ ΔIOUT ≤ IFULL LOAD (V (V IN – VOUT) = 3V IN – VOUT) = 25V 1.7V ≤ (VIN – VOUT) ≤ 15V 100 IOUT = IFULL LOAD 1.25 95 0.45 90 1.24 85 0.44 80 OUTPUT VOLTAGE (V) CURRENT LIMIT (A) 1.23 RIPPLE REJECTION (dB) 75 0.43 70 1.22 65 0.42 1 10 100 1000 1 10 100 1000 1 10 100 1000 TOTAL DOSE – KRADS (Si) TOTAL DOSE – KRADS (Si) TOTAL DOSE – KRADS (Si) RH1085 G01 RH1085 G02 RH1085 G03 rh1085fc 4