1.3 Absolute maximum ratings. 1/ Supply voltage (VCC) ... 20 V Differential input voltage .. 30 V Input voltage .. Supply voltage Output short-circuit duration .. Continuous Power dissipation (PD) .. 800 mW Storage temperature range ... -65C to +150C Lead temperature range (soldering, 60 seconds) .. +300C Junction temperature (TJ) .. -65C to +150C Thermal resistance, junction-to-case (JC) .. See MIL-STD-1835 Thermal resistance, junction-to-ambient (JA): Cases C and K ... 91C/W Case 3 .. 110C/W 1.4 Recommended operating conditions. Ambient operating temperature range (TA) ... -55C to +125C Supply voltage (VCC) ... 15 V 1.5 Radiation features. Maximum total dose available (high dose rate = 50 – 300 rad(Si)/s) ... 100 krad(Si) 2/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http://quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) ______ 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate sensitivity effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions specified in MIL-STD-883, method 1019, condition A. STANDARD SIZE 5962-87771MICROCIRCUIT DRAWINGA DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 G 3 DSCC FORM 2234 APR 97