TABLE IIA. Electrical test requirements. Test requirements Subgroups Subgroups (in accordance with (in accordance with MIL-STD-883, MIL-PRF-38535, table III) method 5005, table I) Device Device Device class M class Q class V Interim electrical 1 1 1 parameters (see 4.2) Final electrical 1,2,3,4, 1/ 2/ 1,2,3,4,5,6 1/ 1,2,3,4,5,6 1/ parameters (see 4.2) 5,6 Group A test 1,2,3,4,5,6,7 1,2,3,4,5,6,7 1,2,3,4,5,6,7 requirements (see 4.4) Group C end-point electrical 1 1 1 2/ parameters (see 4.4) Group D end-point electrical 1 1 1 parameters (see 4.4) Group E end-point electrical --- --- 1, 4 parameters (see 4.4) 1/ PDA applies to subgroup 1. 2/ Delta limits as specified in table IIB shall be required where specified, and the delta limits shall be computed with reference to the previous interim electrical parameters. TABLE IIB. Burn-in and operating life test delta parameters. TA = +25C. 1/ 2/ Limit Delta Parameter Device types Min Max Min Max VOS 01, 03 0.4 mV 100 V 02, 04 0.8 mV 250 V IOS 01, 03 10 nA 5 nA 02, 04 10 nA 5 nA IB 01, 03 25 nA 5 nA 02, 04 25 nA 5 nA 1/ Deltas are performed at room temperature. 2/ 240 hour burn-in and 1,000 hour operating group C life test. STANDARD SIZE 5962-88565MICROCIRCUIT DRAWINGA DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 J9 DSCC FORM 2234 APR 97