Data SheetADIS16375ABSOLUTE MAXIMUM RATINGS Table 3. Stresses above those listed under Absolute Maximum Ratings ParameterRating may cause permanent damage to the device. This is a stress Acceleration rating only; functional operation of the device at these or any Any Axis, Unpowered 2000 g other conditions above those indicated in the operational Any Axis, Powered 2000 g section of this specification is not implied. Exposure to absolute VCC to GND −0.3 V to +3.6 V maximum rating conditions for extended periods may affect Digital Input Voltage to GND −0.3 V to VCC + 0.2 V device reliability. Digital Output Voltage to GND −0.3 V to VCC + 0.2 V Table 4. Package Characteristics Operating Temperature Range −40°C to +105°C Package Typeθ Storage Temperature Range −65°C to +150°C1 JAθJCDevice Weight 24-Lead Module (ML-24-6) 20.5 6.3 25 g 1 Extended exposure to temperatures outside the specified temperature range of −40°C to +105°C can adversely affect the accuracy of the factory calibration. For best accuracy, store the parts within the specified operating range of −40°C to +105°C. ESD CAUTION Rev. D | Page 7 of 28 Document Outline Features Applications Functional Block Diagram General Description Revision History Specifications Timing Specifications Timing Diagrams Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Basic Operation Register Structure SPI Communication Device Configuration Dual Memory Structure Reading Sensor Data User Registers Output Data Registers Inertial Sensor Data Format Rotation Rate (Gyroscope) Acceleration Delta Angles Velocity Changes Internal Temperature Status/Alarm Indicators Product Identification Digital Signal Processing Sampling Plan Averaging/Decimation Filter FIR Filter Banks Filter Memory Organization Default Filter Performance Calibration Manual Bias Correction Manual Sensitivity Correction Bias Null Command Restoring Factory Calibration Linear Acceleration on Effect on Gyroscope Bias Point of Percussion Alignment Alarms Static Alarm Use Dynamic Alarm Use Alarm Reporting Alarm Example System Controls Global Commands Software Reset Automatic Self Test Memory Management Flash Memory Test General-Purpose I/O Data-Ready Indicator Input Sync/Clock Control General-Purpose I/O Control Power Management Real-Time Clock Configuration/Data Applications Information Mounting Tips Evaluation Tools Breakout Board, ADIS16IMU/PCBZ PC-Based Evaluation, EVAL-ADIS2 Power Supply Considerations Outline Dimensions Ordering Guide