TABLE I. Electrical performance characteristics. Conditions 1/ Test Symbol -55°C ≤ TA ≤ +125°C Group A Device Limits 2/ Unit unless otherwise specified subgroups type Min Max Input offset voltage VOS VCM = 0 V 1 01 -700 +700 µV 2,3 -1500 +1500 Gain error GE VIN = ±10 V, no load 1 01 -0.008 +0.008 % 2,3 -0.020 +0.020 Input voltage range IVR 3/ 1,2,3 01 -10 +10 V Common mode rejection CMRR VCM = ±10 V 1 01 80 dB ratio 2,3 75 Power supply rejection PSRR VS = ±6 V to ±18 V 1 01 10 µV/V ratio 2,3 20 Output swing VO RL = 2 kΩ 1,2,3 01 -12 +12 V Supply current ISY No load 1 01 3.5 mA 2,3 4 Slew rate SR RL = 2 kΩ, TA = +25°C 4 01 6 V/µs 1/ Unless otherwise specified, VS = ±15 V, source resistance (RS) = 50 Ω, and common mode voltage (VCM) = 0 V. 2/ The algebraic convention, whereby the most negative value is a minimum and the most positive is a maximum, is used in this table. Negative current shall be defined as conventional current flow out of a device terminal. 3/ Input voltage range (IVR) is guaranteed by the common mode rejection ratio (CMRR) test. STANDARD SIZE 5962-95639MICROCIRCUIT DRAWINGA DEFENSE SUPPLY CENTER COLUMBUS REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 B 5 DSCC FORM 2234 APR 97 Document Outline DEPARTMENT OF DEFENSE SPECIFICATION DEPARTMENT OF DEFENSE STANDARDS