Datasheet AD8306 (Analog Devices) - 4

HerstellerAnalog Devices
Beschreibung5 MHz TO 400 MHz, 100 dB High Precision Limiting - Logarithmic Amplifier
Seiten / Seite25 / 4 — STANDARD. 5962-98646. MICROCIRCUIT DRAWING
Dateiformat / GrößePDF / 412 Kb
DokumentenspracheEnglisch

STANDARD. 5962-98646. MICROCIRCUIT DRAWING

STANDARD 5962-98646 MICROCIRCUIT DRAWING

Modelllinie für dieses Datenblatt

Textversion des Dokuments

1.5 Radiation features. Maximum total dose available (dose rate = 50 – 300 rads(Si)/s): For device type 02 ... 100 krads(Si) 4/ Maximum total dose available (dose rate ≤ 0.10 rads(Si)/s): For device type 03 ... 50 krads(Si) 5/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https://assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535 and herein for device classes Q and V. 3.2.1 Case outline. The case outline shall be in accordance with 1.2.4 herein. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1. 3.2.3 Block diagram. The block diagram shall be as specified on figure 2. 3.2.4 Radiation exposure circuit. The radiation exposure circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing and acquiring activity upon request. _____ 4/ Device type 02 may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. The radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition A to a maximum total dose of 100 krads(Si). 5/ The device type 03 radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition D to a maximum total dose of 50 krads (Si).
STANDARD
SIZE
5962-98646 MICROCIRCUIT DRAWING A
DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 D 4 DSCC FORM 2234 APR 97 Document Outline DEPARTMENT OF DEFENSE SPECIFICATION DEPARTMENT OF DEFENSE STANDARDS