Datasheet ADUM3190 (Analog Devices) - 6

HerstellerAnalog Devices
Beschreibung2.5kV rms Isolated Error Amplifier
Seiten / Seite19 / 6 — Data Sheet. ADuM3190. PACKAGE CHARACTERISTICS. Table 2. Parameter. …
RevisionA
Dateiformat / GrößePDF / 596 Kb
DokumentenspracheEnglisch

Data Sheet. ADuM3190. PACKAGE CHARACTERISTICS. Table 2. Parameter. Symbol. Min Typ. Max Unit. Test Conditions/Comments

Data Sheet ADuM3190 PACKAGE CHARACTERISTICS Table 2 Parameter Symbol Min Typ Max Unit Test Conditions/Comments

Modelllinie für dieses Datenblatt

Textversion des Dokuments

link to page 6 link to page 8 link to page 18
Data Sheet ADuM3190 PACKAGE CHARACTERISTICS Table 2. Parameter Symbol Min Typ Max Unit Test Conditions/Comments
RESISTANCE Input-to-Output1 RI-O 1013 Ω CAPACITANCE Input-to-Output1 CI-O 2.2 pF f = 1 MHz Input Capacitance2 CI 4.0 pF IC JUNCTION-TO-AMBIENT THERMAL Thermocouple located at center of package underside RESISTANCE 16-Lead QSOP θJA 76 °C/W 1 The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together. 2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM3190 is approved by the organizations listed in Table 3. See Table 8 and the Insulation Lifetime section for recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 3. UL CSA VDE
Recognized Under 1577 Component Approved under CSA Component Certified according to DIN V VDE V 0884-10 Recognition Program1 Acceptance Notice #5A (VDE V 0884-10): 2006-122 Single Protection, 2500 V rms Isolation Basic insulation per CSA 60950-1-03 and Reinforced insulation, 565 V peak Voltage, 16-Lead QSOP IEC 60950-1, 400 V rms (565 V peak) maximum working voltage File E214400 File 205078 File 2471900-4880-0001 1 In accordance with UL 1577, each ADuM3190 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec (current leakage detection limit = 5 µA). 2 In accordance with DIN V VDE V 0884-10, each ADuM3190 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS Table 4. Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 3.8 min mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) 3.1 min mm Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303, Part 1 Isolation Group II Material Group DIN VDE 0110, 1/89, Table 1
RECOMMENDED OPERATING CONDITIONS Table 5. Parameter Symbol Min Max Unit
OPERATING TEMPERATURE BY MODEL TA ADuM3190A/ADuM3190B −40 +85 °C ADuM3190S/ADuM3190T −40 +125 °C SUPPLY VOLTAGES1 VDD1, VDD2 3.0 20 V INPUT SIGNAL RISE AND FALL TIMES tR, tF 1.0 ms 1 All voltages are relative to their respective grounds. Rev. A | Page 5 of 18 Document Outline Features Applications General Description Functional Block Diagram Table of Contents Revision History Specifications Package Characteristics Regulatory Information Insulation and Safety Related Specifications Recommended Operating Conditions DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Test Circuits Applications Information Theory of Operation Accuracy Circuit Operation Isolated Amplifier Circuit Operation Application Block Diagram Setting the Output Voltage DOSA Module Application DC Correctness and Magnetic Field Immunity Insulation Lifetime Packaging and Ordering Information Outline Dimensions Ordering Guide Automotive Products