1.3 Absolute maximum ratings. 1/ Supply voltage range: 2/ VDD1, VDD2 ... -0.5 V to +24 V VREG1, VREG2 ... -0.5 V to +3.6 V Input voltage range (+IN, -IN) ... -0.5 V to +3.6 V Output voltage range: REFOUT, REFOUT1, COMP, EAOUT ... -0.5 V to +3.6 V EAOUT2 ... -0.5 V to +5.5 V Output current per output pin range ... -11 mA to +11 mA Common mode transients range .. -100 kV/s to +100 kV/s 3/ Junction temperature range (TJ) .. -55C to +150C Storage temperature range (TSTG) .. -65C to +150C 1.4 Recommended operating conditions. 4/ Supply voltages ( VDD1, VDD2 ) ... 3.0 V to +20 V 2/ Input signal rise and fall times ( tR, tF ) .. 1.0 ms maximum Ambient operating temperature range (TA) .. -55C to +125C 1.5 Maximum continuous working voltage. 5/ AC voltage at a 50 year minimum lifetime: Bipolar waveform .. 560 V peak maximum Unipolar waveform .. 1131 V peak maximum DC voltage at a 50 year minimum lifetime .. 1131 V peak maximum 1/ Stresses beyond those listed under “absolute maximum rating” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 2/ All voltages are relative to their respective grounds. 3/ Refers to common mode transients across the insulation barrier. Common mode transients exceeding the absolute maximum ratings may cause latch up or permanent damage. 4/ Use of this product beyond the manufacturers design rules or stated parameters is done at the user’s risk. The manufacturer and/or distributor maintain no responsibility or liability for product used beyond the stated limits. 5/ Refers to the continuous voltage magnitude imposed across the isolation barrier. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/17602 REV PAGE 3