AD9280ABSOLUTE MAXIMUM RATINGS* *Stresses above those listed under Absolute Maximum Ratings may cause perma- nent damage to the device. This is a stress rating only; functional operation of the With device at these or any other conditions above those indicated in the operational Respect sections of this specification is not implied. Exposure to absolute maximum ParametertoMinMaxUnits ratings for extended periods may effect device reliability. AVDD AVSS –0.3 +6.5 V DRVDD DRVSS –0.3 +6.5 V AVSS DRVSS –0.3 +0.3 V AVDD DRVDD –6.5 +6.5 V MODE AVSS –0.3 AVDD + 0.3 V CLK AVSS –0.3 AVDD + 0.3 V Digital Outputs DRVSS –0.3 DRVDD + 0.3 V AIN AVSS –0.3 AVDD + 0.3 V VREF AVSS –0.3 AVDD + 0.3 V REFSENSE AVSS –0.3 AVDD + 0.3 V REFTF, REFTB AVSS –0.3 AVDD + 0.3 V REFTS, REFBS AVSS –0.3 AVDD + 0.3 V Junction Temperature +150 °C Storage Temperature –65 +150 °C Lead Temperature 10 sec +300 °C AVDDDRVDDAVDDAVDDAVDDAVDDDRVSSDRVSSAVSSAVSSAVSSAVSSAVSS a. D0–D7, OTR b. Three-State, Standby, Clamp c. CLK AVDDAVDDREFTF 22REFBS 25AVDDAVSSAVSSAVDDAVDDREFBF 2421REFTSAVSSAVSSAVSS d. AIN e. Reference AVDDAVDDAVDDAVDDAVSSAVSSAVSSAVSS f. CLAMPIN g. MODE h. REFSENSE i. VREF Figure 2. Equivalent Circuits CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily WARNING! accumulate on the human body and test equipment and can discharge without detection. Although the AD9280 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD ESD SENSITIVE DEVICE precautions are recommended to avoid performance degradation or loss of functionality. –4– REV. E Document Outline FEATURES PRODUCT DESCRIPTION PRODUCT HIGHLIGHTS FUNCTIONAL BLOCK DIAGRAM AD9280-SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION PIN FUNCTION DESCRIPTIONS DEFINITIONS OF SPECIFICATIONS TYPICAL CHARACTERIZATION CURVES APPLYING THE AD9280 Theory of Operation Operational Modes Summary of Modes Voltage Reference Reference Buffer Analog Input Special Input and Reference Overview REFERENCE OPERATION Internal Reference Operation External Reference Operation STANDBY OPERATION CLAMP OPERATION Clamp Circuit Example DRIVING THE ANALOG INPUT DIFFERENTIAL INPUT OPERATION AD876-8 MODE OF OPERATION CLOCK INPUT DIGITAL INPUTS AND OUTPUTS APPLICATIONS Direct IF Down Conversion Using the AD9280 Grounding and Layout Rules Digital Outputs Three-State Outputs OUTLINE DIMENSIONS Ordering Guide REVISION HISTORY