Datasheet AD10200 (Analog Devices) - 5

HerstellerAnalog Devices
BeschreibungDual Channel, 12-Bit, 105 MSPS IF Sampling A/D Converter With Analog Input Signal Conditioning
Seiten / Seite20 / 5 — AD10200. ABSOLUTE MAXIMUM RATINGS1, 2. Table I. Output Coding (VREF = 2.5 …
RevisionB
Dateiformat / GrößePDF / 1.5 Mb
DokumentenspracheEnglisch

AD10200. ABSOLUTE MAXIMUM RATINGS1, 2. Table I. Output Coding (VREF = 2.5 V) (Two’s Complement). Code. AIN (V). Digital Output

AD10200 ABSOLUTE MAXIMUM RATINGS1, 2 Table I Output Coding (VREF = 2.5 V) (Two’s Complement) Code AIN (V) Digital Output

Modelllinie für dieses Datenblatt

Textversion des Dokuments

AD10200 ABSOLUTE MAXIMUM RATINGS1, 2 Table I. Output Coding (VREF = 2.5 V) (Two’s Complement)
VDD . 6 V V
Code AIN (V) Digital Output
CC . 6 V Analog Inputs . 5 V p-p(18 dBm) +2047 +1.024 0111 1111 1111 Digital Inputs . –0.5 V to VDD + 0.5 V • • • Digital Output Current . 20 mA • • • Operating Temperature . –50°C to +125°C 0 0 0000 0000 0000 Storage Temperature . –65°C to +150°C –1 –0.00049 1111 1111 1111 Maximum Junction Temperature . 175°C • • • Maximum Case Temperature . 150°C • • • NOTES –2048 –1.024 1000 0000 0000 1Stresses above those listed under Absolute Maximum Ratings may cause perma- nent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions outside of those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum ratings for extended periods may affect device reliability. 2Typical thermal impedances for “Z” package: θJC = 2.22°C/W; θJA = 24.3°C/W.
EXPLANATION OF TEST LEVELS Test Level
I. 100% production tested. II. 100% production tested at 25°C and sample tested at specific temperatures. III. Sample tested only. IV. Parameter is guaranteed by design and characterization testing. V. Parameter is a typical value only. VI. 100% production tested at 25°C; guaranteed by design and characterization testing for industrial temperature range.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although
WARNING!
the AD10200 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
ESD SENSITIVE DEVICE
recommended to avoid performance degradation or loss of functionality.
Revision History Location Page 8/2016 Data Sheet changed from REV. A to REV. B.
Change Operating Temperature Range. .1, 4 Moved Ordering Guide . 19 Changes to Ordering Guide . 19 Updated Outline Dimensions . 19
Data Sheet changed from REV. 0 to REV. A.
Edit to ABSOLUTE MAXIMUM RATINGS . 4 Edit to Figure 5 . 9 Edit to ENCODE Inputs section . 10 Edit to Figure 9a . 12 –4– REV. B