Datasheet Texas Instruments OPA564AIDWP — Datenblatt
Hersteller | Texas Instruments |
Serie | OPA564 |
Artikelnummer | OPA564AIDWP |
1,5 A, 24 V, 17 MHz, Leistungsverstärker 20-SO PowerPAD -40 bis 85
Datenblätter
1.5A, 24V, 17MHz Power Operational Amplifier datasheet
PDF, 1.7 Mb, Revision: E, Datei veröffentlicht: Jan 28, 2011
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | No |
Verpackung
Pin | 20 |
Package Type | DWP |
Industry STD Term | HSOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 25 |
Carrier | TUBE |
Device Marking | OPA564 |
Width (mm) | 7.52 |
Length (mm) | 12.82 |
Thickness (mm) | 2.55 |
Pitch (mm) | 1.27 |
Max Height (mm) | 2.65 |
Mechanical Data | Herunterladen |
Parameter
Additional Features | Adj Current Limit,Shutdown |
Architecture | FET |
CMRR(Min) | 70 dB |
CMRR(Typ) | 90 dB |
GBW(Typ) | 17 MHz |
Input Bias Current(Max) | 100 pA |
Iq per channel(Max) | 50 mA |
Iq per channel(Typ) | 39 mA |
Number of Channels | 1 |
Offset Drift(Typ) | 10 uV/C |
Operating Temperature Range | -40 to 85 C |
Output Current(Typ) | 1500 mA |
Package Group | SO PowerPAD |
Package Size: mm2:W x L | 20SO PowerPAD: 133 mm2: 10.405 x 12.825(SO PowerPAD) PKG |
Rail-to-Rail | In to V- |
Rating | Catalog |
Slew Rate(Typ) | 40 V/us |
Total Supply Voltage(Max) | 24 +5V=5, +/-5V=10 |
Total Supply Voltage(Min) | 7 +5V=5, +/-5V=10 |
Vos (Offset Voltage @ 25C)(Max) | 20 mV |
Öko-Plan
RoHS | Compliant |
Anwendungshinweise
- Biasing Considerations for OPA564 During Enabled and Disabled StatesPDF, 130 Kb, Datei veröffentlicht: Mar 6, 2011
The OPA564 is a high-voltage, high-current, wide-bandwidth operational amplifier suitable for many applications. Among the many features available on the OPA564 is a disabled mode that is designed to be used for power savings in time multiplexed systems such as powerline communications. When using an op amp that can be placed into either the enabled state or disabled state (shutdown), it is critic - Power Amplifier Stress and Power Handling LimitationsPDF, 55 Kb, Datei veröffentlicht: Sep 27, 2000
To achieve reliable power amplifier designs you must consider the stress on the amplifier compared to its power handling limitations. Power handling limits are specified by the Safe Operating Area (SOA) curves of the power amp. Stress on the amplifier depends on amplifier load and signal conditions which can be evaluated with straightforward techniques.
Modellreihe
Serie: OPA564 (4)
- OPA564AIDWD OPA564AIDWDR OPA564AIDWP OPA564AIDWPR
Herstellerklassifikation
- Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Power Op Amps