Datasheet Texas Instruments PGA900AYZSR — Datenblatt

HerstellerTexas Instruments
SeriePGA900
ArtikelnummerPGA900AYZSR
Datasheet Texas Instruments PGA900AYZSR

Programmierbarer Resistive Sensing Conditioner mit digitalen und analogen Ausgängen 36-DSBGA -40 bis 150

Datenblätter

PGA900 Programmable Resistive Sensing Conditioner with Digital and Analog Outputs datasheet
PDF, 1.7 Mb, Revision: A, Datei veröffentlicht: May 12, 2015
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusPreview (Device has been announced but is not in production. Samples may or may not be available)
Manufacture's Sample AvailabilityNo

Verpackung

Pin3636
Package TypeYZSYZS
Industry STD TermDSBGADSBGA
JEDEC CodeS-XBGA-NS-XBGA-N
Package QTY15001500
Device MarkingPGA900AYZS
Thickness (mm).4.4
Pitch (mm).5.5
Max Height (mm).625.625
Mechanical DataHerunterladenHerunterladen

Parameter

# Input Channels2
InterfaceSPI, UART, I2C, PWM, OWI, Ratiometric Analog Voltage, 4-20mA
Operating Temperature Range-40 to 150 C
Package GroupDSBGA
Package Size: mm2:W x LSee datasheet (DSBGA) PKG
RatingCatalog
Resolution24 Bits
Sample Rate (max)15.6k SPS
Vs(Max)30 V
Vs(Min)3.3 V

Öko-Plan

RoHSCompliant

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: PGA900EVM
    PGA900 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Anwendungshinweise

  • PGA900, PGA300 and PGA305 Use Case for HVAC Applications
    PDF, 103 Kb, Datei veröffentlicht: May 2, 2017
  • PGA900, PGA300 and PGA305 Use Case for the Pressure Transmitter Applications
    PDF, 104 Kb, Datei veröffentlicht: May 2, 2017
  • System Noise Analysis of a Resistive Bridge Pressure Sensor Connected to the PGA
    PDF, 195 Kb, Datei veröffentlicht: Jul 7, 2015
    In this application note we will do a system noise analysis of the PGA900 connected to a resistive bridgepressure sensor. First, we will measure the noise referred to the output for the PGA900. Then, using these measurement results we will calculate the noise-free resolution and effective resolution of the PGA900 forits analog-to-digital converter operating at 64- and 128-Вµs output data
  • PGA900, PGA300 and PGA305 Use Case for Weight Scale (Load Cell) Applications
    PDF, 87 Kb, Datei veröffentlicht: May 1, 2017
  • PGA900 DAC Output Stability Application Note
    PDF, 253 Kb, Datei veröffentlicht: Mar 4, 2015
    Capacitive load drive is one of the most common causes of operational amplifier stability issues. The load capacitance, CL, interacts with the open-loop output impedance of the amplifier, ZO, by adding a single or double pole in the open-loop response. The additional pole or poles degrades the circuit phase margin, resulting in transient overshoot and ringing, ac gain peaking
  • PGA900 as 4- to 20-mA Current Loop Transmitter
    PDF, 238 Kb, Datei veröffentlicht: May 7, 2015
    This application note shows the PGA900 used as a 2-wire, 4- to 20-mA current loop transmitter, a common method of transmitting sensor information in industrial process-monitoring applications. Transmitting sensor information (physical parameter measurements) through a current loop is particularly useful when the information must be sent to a remote location over long distances (1000 feet or more).
  • Understanding Open Loop Output Impedance of the PGA900 DAC Gain Amplifier (Rev. A)
    PDF, 253 Kb, Revision: A, Datei veröffentlicht: May 19, 2015
    The open-loop output impedance (ZO) of an operational amplifier is one of the most important specifications. Proper understanding of ZO over frequency is crucial for the understanding of loop gain, bandwidth, and stability analysis.This application note provides an in-depth understanding of the PGA900 ZO magnitude over frequency. The effects of temperature, power
  • Connecting PGA900 Instrumentation Amplifier to Resistive Bridge Sensor
    PDF, 1.1 Mb, Datei veröffentlicht: May 8, 2015
    Understanding the input and output limitations of an instrumentation amplifier (IA) is important in interfacing a resistive bridge sensor to the PGA900. Adjusting the common mode voltage of the input signal appropriately allows us to maximize the gain. Maximizing the gain yields the largest output signal span for the 24-bit analog-to-digital converter (ADC). The largest signal span maximizes the c
  • Understanding Open Loop Gain of the PGA900 DAC Gain Amplifier
    PDF, 338 Kb, Datei veröffentlicht: Apr 2, 2015
    The open-loop gain (AOL) of an operational amplifier is one of the most important specifications. Proper understanding of AOL at DC and over frequency is crucial for the understanding of closed-loop gain, bandwidth, and stability analysis.This application note provides an in-depth understanding of the PGA900 AOL magnitude and phase over frequency. The effects of
  • Ratiometric measurement in the context of LVDT-sensor signal conditioning
    PDF, 228 Kb, Datei veröffentlicht: Jul 21, 2016
  • Design tips for a resistive-bridge pressure sensor in industrial process-control
    PDF, 240 Kb, Datei veröffentlicht: Jul 24, 2015
  • Analog Applications Journal 3Q 2015
    PDF, 7.1 Mb, Datei veröffentlicht: Jul 24, 2015

Modellreihe

Serie: PGA900 (3)

Herstellerklassifikation

  • Semiconductors > Sensing Products > Resistive Bridge Sensor Signal Conditioners