Datasheet Texas Instruments OPA196IDR — Datenblatt

HerstellerTexas Instruments
SerieOPA196
ArtikelnummerOPA196IDR
Datasheet Texas Instruments OPA196IDR

36-V-Allzweckverstärker mit geringem Stromverbrauch und MUX-freundlichem Eingang 8-SOIC -40 bis 125

Datenblätter

OPAx196 36-V, Low-Power, Low Offset Voltage, Rail-to-Rail Operational Amplifier datasheet
PDF, 3.1 Mb, Datei veröffentlicht: Jul 10, 2017
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin8
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY2500
CarrierLARGE T&R
Device MarkingOPA196
Width (mm)3.91
Length (mm)4.9
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical DataHerunterladen

Parameter

Additional FeaturesEMI Hardened,High Cload Drive
ArchitectureCMOS
CMRR(Min)120 dB
CMRR(Typ)140 dB
GBW(Typ)2.5 MHz
Input Bias Current(Max)20 pA
Iq per channel(Max)0.2 mA
Iq per channel(Typ)0.14 mA
Number of Channels1
Offset Drift(Typ)0.5 uV/C
Operating Temperature Range-40 to 125 C
Output Current(Typ)65 mA
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
Rail-to-RailIn,Out
RatingCatalog
Slew Rate(Typ)5.5 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)4.5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)15 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)0.1 mV

Öko-Plan

RoHSCompliant

Anwendungshinweise

  • MUX-Friendly: Definition and Benefits
    PDF, 212 Kb, Datei veröffentlicht: Sep 18, 2017
  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revision: A, Datei veröffentlicht: Mar 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps