Datasheet Texas Instruments HPA02235YZFR — Datenblatt
Hersteller | Texas Instruments |
Serie | BQ27520-G3 |
Artikelnummer | HPA02235YZFR |
Systemseitige Impedanzspur ™ Kraftstoffanzeige mit integriertem LDO 15-DSBGA -40 bis 85
Datenblätter
System-Side Impedance Trackв„ў Fuel Gauge With Integrated LDO .. datasheet
PDF, 1.6 Mb, Datei veröffentlicht: Dec 16, 2011
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | NRND (Not recommended for new designs) |
Manufacture's Sample Availability | No |
Verpackung
Pin | 15 |
Package Type | YZF |
Industry STD Term | DSBGA |
JEDEC Code | R-XBGA-N |
Package QTY | 3000 |
Carrier | LARGE T&R |
Device Marking | BQ27520 |
Width (mm) | 2.75 |
Length (mm) | 1.75 |
Pitch (mm) | .5 |
Max Height (mm) | .625 |
Mechanical Data | Herunterladen |
Öko-Plan
RoHS | Compliant |
Design Kits und Evaluierungsmodule
- Evaluation Modules & Boards: BQ27520EVM
System-Side Impedance TrackВ™ Battery Fuel Gauge Evaluation Module | Gas Gauge
Lifecycle Status: Active (Recommended for new designs)
Anwendungshinweise
- bq20z70, bq20z75, bq20z90, and bq20z95 Voltage Current & Measurement AccuracyPDF, 58 Kb, Datei veröffentlicht: Mar 18, 2008
This document describes the accuracy capabilities of the bq20z70, bq20z75, bq20z90, and bq20z95 solutions. All data shown in this document was gathered empirically - Multicell Li-Ion and Li-Polymer Battery Gas-Gauge Host Side Application (Rev. A)PDF, 59 Kb, Revision: A, Datei veröffentlicht: Jan 25, 2011
bq2750x Multicell Li-Ion and Li-Polymer Battery Gas-Gauge Host Side Application Using bq2750x - Host System Calibration Method (Rev. B)PDF, 140 Kb, Revision: B, Datei veröffentlicht: May 19, 2016
To add improvements to the Impedance Trackв„ў algorithm, changes have been made to free up firmwarecode space. In the process of freeing up code space, the calibration calculations are no longerautomatically performed by the gauge but must be performed by the host and the results written back tothe gauge. This application note provides a flow on how to implement the calibration algorithm on a - bq27520-G2 to bq27520-G3 Change ListPDF, 43 Kb, Datei veröffentlicht: Feb 7, 2012
- bq27520-G1 to bq27520-G2 Change ListPDF, 60 Kb, Datei veröffentlicht: Feb 7, 2012
- Using the bq24075 Charger and bq27500/1 Fuel GaugePDF, 173 Kb, Datei veröffentlicht: Nov 3, 2008
Using the bq24075 Charger and bq27500/1 Fuel Gauge Together - bq27500-V120 to bq27500-V130 Change ListPDF, 40 Kb, Datei veröffentlicht: Dec 3, 2009
This document describes the changes made between firmware versions bq27500-V120 and bq27500-V130. The latest ordering information and data sheet is on the TI Web site. - bq27520-G3 to bq27520-G4 Change ListPDF, 38 Kb, Datei veröffentlicht: Oct 23, 2012
bq27520-G3, bq27520-G4, bq27520-G2, bq27520-G1, bq27520EVM bq27520-G3 to bq27520-G4 Change List - Quick Start Guide for bq2750x Family Gas GaugePDF, 2.7 Mb, Datei veröffentlicht: Jan 23, 2008
This application report provides you a design process overview, procedures to use the evaluation module and software, and helpful troubleshooting techniques. - bq27500-V100 to bq27500-V120 Change ListPDF, 46 Kb, Datei veröffentlicht: Dec 2, 2008
This document describes the change made from bq27500-V100 to bq27500-V120. The latest ordering information and data sheet is on the TI Web site. Note that bq27500-V100 uses FW version 1.08 and the bq27500-V120 uses FW version 1.20. - Configuring the bq27500 Data Flash (Rev. A)PDF, 1.5 Mb, Revision: A, Datei veröffentlicht: Feb 1, 2008
The bq27500 has many data flash constants that can configure the device with various different options for most features. The data flash of the bq27500 is split into sections, which are described in detail in this document. - Feature Set Comparison of bq27x00, bq27x10, bq27500, and bq27510 (Rev. A)PDF, 65 Kb, Revision: A, Datei veröffentlicht: Dec 2, 2008
Feature Set Comparison of bq27x00, bq27x10, bq27500 and bq27510 - WinCE/Linux Drivers for bq275xx Fuel GaugePDF, 188 Kb, Datei veröffentlicht: Mar 17, 2011
The bq275xx gas gauge integrated circuits (IC) can use an I2C line for communication with the host system. It is necessary to allow application-layer software on the host system to access parameters made available by the gas gauge IC. Multiple levels of abstraction are between the gauge and a given application. This document describes an example implementation of each of these layers in an effo - Achieving the Successful Learning CyclePDF, 46 Kb, Datei veröffentlicht: May 12, 2011
bq27500, bq27501, bq27510, bq27505, bq27541, bq27520 Achieving the Successful Learning Cycle - Updating bq275xx Firmware at Production (Rev. A)PDF, 107 Kb, Revision: A, Datei veröffentlicht: Feb 21, 2011
bq27500 bq27500-V100 bq27500-V120 bq27500-V130 bq27501 bq27505 bq27505-J2 bq27505-J3 bq275 Updating bq275xx Firmware at Production - Going to Production With the bq275xx (Rev. F)PDF, 1.1 Mb, Revision: F, Datei veröffentlicht: Oct 9, 2014
- Improving Battery Safety, Charging, and Fuel Gauging in Portable Media AppsPDF, 570 Kb, Datei veröffentlicht: Mar 11, 2009
- Updating Firmware with the bq2750x and EVM (Rev. A)PDF, 955 Kb, Revision: A, Datei veröffentlicht: Jul 22, 2008
This application report provides the procedure to update bq2750x firmware and the learned golden image (*.DFI file) in bq27500 data flash from the previous firmware version. - How to Generate Golden Image for Single-Cell Impedance Track(TM) DevicesPDF, 964 Kb, Datei veröffentlicht: Jan 7, 2010
Texas Instruments advanced fuel gauges, employing the Impedance Trackв„ў algorithm, offer an unmatched array of features and benefits. Sometimes, however, the learning cycle to generate the golden image may seem a little challenging. In addition, determining the correct chemistry model and producing the golden image file can be time consuming. This application report describes the necessary p - Q1 2009 Issue Analog Applications JournalPDF, 1.4 Mb, Datei veröffentlicht: Mar 11, 2009
- Impedance Track Fuel Gauge Accuracy Test for GSM Phone ApplicationsPDF, 393 Kb, Datei veröffentlicht: Mar 21, 2008
The Texas Instruments Impedance Trackв„ў (IT) fuel gauge is designed for reporting remaining battery capacity and run time accurately. To effectively accomplish this reporting a real application environment must be used for test results. The test board should be designed as similar to the real application circuit as possible. This application report outlines the procedure for implementing an accurac - Single Cell Gas Gauge Application BookPDF, 9.7 Mb, Datei veröffentlicht: Jul 28, 2008
- Using I2C Communication With the bq275xx Series of Fuel Gauges (Rev. B)PDF, 53 Kb, Revision: B, Datei veröffentlicht: May 15, 2014
- Host-Side Gas-Gauge-System Design Considerations for Single-Cell Handheld AppsPDF, 152 Kb, Datei veröffentlicht: Oct 12, 2007
- Theory and Implementation of Impedance Track Battery Fuel-Gauging AlgorithmPDF, 608 Kb, Datei veröffentlicht: Jan 31, 2008
This application report outlines the theory of Impedance Trackв„ў (IT) technology used in the bq2750x series of fuel gauge ICs for single-cell Li-ion applications (e.g., smart phones, media players, and PDAs). The implementation of the IT algorithm in the bq2750x family is reviewed, and the settings of data flash constants associated with the fuel-gauging algorithm is described in detail. - Single Cell Impedance Track Printed-Circuit Board LayoutPDF, 403 Kb, Datei veröffentlicht: Feb 22, 2008
bq20z70/90 Printed-Circuit Board Layout Guide - Single Cell Gas Gauge Circuit DesignPDF, 154 Kb, Datei veröffentlicht: Feb 22, 2008
- MSP430 Microcontroller SW for Handheld Fuel Gauges and Battery Authentication (Rev. A)PDF, 350 Kb, Revision: A, Datei veröffentlicht: May 26, 2010
MSP430, bq26100, bq26100EVM, bq26150, bq26150EVM, bq26500, bq27000, bq27000EVM, bq27200, b MSP430 Microcontroller Software for Handheld Fuel Gauge & Battery Authentication
Modellreihe
Serie: BQ27520-G3 (3)
- BQ27520YZFR-G3 BQ27520YZFT-G3 HPA02235YZFR
Herstellerklassifikation
- Semiconductors > Power Management > Battery Management Products > Battery Fuel Gauge