Datasheet Linear Technology LT1002CN#PBF — Datenblatt
Hersteller | Linear Technology |
Serie | LT1002 |
Artikelnummer | LT1002CN#PBF |
Dualer, abgestimmter Präzisions-Operationsverstärker
Datenblätter
Datasheet LT1002
PDF, 188 Kb, Sprache: en, Datei hochgeladen: Apr 21, 2017, Seiten: 16
Dual, Matched Precision Operational Amplifier
Dual, Matched Precision Operational Amplifier
Auszug aus dem Dokument
Preise
Verpackung
Package | N-14 |
Package Code | N |
Package Index | 05-08-1510 (N14) |
Parameter
Number of Channels | 2 |
Unity Gain BW | 0.8 MHz |
Av Min Stable | 1 V/V |
Avol | 58 dB |
Common Mode Rejection Ratio | 126 dB |
Cload | 20000 pF |
Design Tools | LTspice File |
Enoise 1/f Corner | 4 Hz |
Enoise Density | 9.6 nV/rtHz |
Export Control | no |
Ibias | 0.6 nA |
Inoise | 0.1 pA/rtHz |
Inoise 1/f Corner | 70 Hz |
Ios | 0.0003 µA |
Iout | 25 mA |
Isupply | 1.53 mA |
LF Enoise | 0.35 µVPP |
Operating Temperature Range | 0 to 70 °C |
Over-the-Top | no |
PSRR | 123 dB |
Rail-to-Rail In | no |
Rail-to-Rail Out | no |
SR | 0.25 V/µs |
Shutdown | no |
Single Supply | no |
Type | VFB |
VinCM High (from V+) | 0.9 V |
VinCM Low (from V-) | 0.9 V |
Voh (from V+) | 1 V |
Vol (from V-) | 1 V |
Vos | 0.02 mV |
Vos TC | 0.2 µV/C |
Vs Max | 44 V |
Vs Min | 6 V |
Öko-Plan
RoHS | Compliant |
Anwendungshinweise
- High Speed Comparator Techniques &mdash AN13PDF, 1.1 Mb, Datei veröffentlicht: Apr 1, 1985
The AN13 is an extensive discussion of the causes and cures of problems in very high speed comparator circuits. A separate applications section presents circuits, including a 0.025% accurate 1Hz to 30MHz V/F converter, a 200ns 0.01% sample-hold and a 10MHz fiber-optic receiver. Five appendices covering related topics complete this note.Auszug aus dem Dokument - Thermal Techniques in Measurement and Control Circuitry &mdash AN5PDF, 175 Kb, Datei veröffentlicht: Dec 1, 1984
6 applications utilizing thermally based circuits are detailed. Included are a 50MHz RMS to DC converter, and anemometer, a liquid flow meter and others. A general discussion of thermodynamic considerations involved in circuitry is also presented.Auszug aus dem Dokument - Applications of New Precision Op Amps &mdash AN6PDF, 784 Kb, Datei veröffentlicht: Jan 1, 1985
Application considerations and circuits for the LT1001 and LT1002 single and dual precision amplifiers are illustrated in a number of circuits, including strain gauge signal conditioners, linearized platinum RTD circuits, an ultra precision dead zone circuit for motor servos and other examples.
Konstruktionshinweise
- Updated Operational Amplifier Selection Guide for Optimum Noise Performance &mdash DN140PDF, 74 Kb, Datei veröffentlicht: Oct 1, 1996Auszug aus dem Dokument
- 3V Operation of Linear Technology Op Amps &mdash DN56PDF, 78 Kb, Datei veröffentlicht: Feb 1, 1992Auszug aus dem Dokument
Modellreihe
Serie: LT1002 (2)
- LT1002ACN#PBF LT1002CN#PBF
Herstellerklassifikation
- Signal Conditioning > Amplifiers > Operational Amplifiers (Op Amps) > Precision Amplifiers (Vos | Low Noise Amplifiers ( | High Voltage Amplifiers (>12V)
Andere Namen:
LT1002CNPBF, LT1002CN PBF