Datasheet Texas Instruments SN65LBC182 — Datenblatt

HerstellerTexas Instruments
SerieSN65LBC182
Datasheet Texas Instruments SN65LBC182

Halbduplex-Transceiver mit 15 kV ESD und 1/4 UL

Datenblätter

SN65LBC182, SN75LBC182 Differential Bus Transceiver datasheet
PDF, 877 Kb, Revision: A, Datei veröffentlicht: Mar 25, 2005
Auszug aus dem Dokument

Preise

Status

SN65LBC182DSN65LBC182DG4SN65LBC182DRSN65LBC182DRG4SN65LBC182PSN65LBC182PE4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoYesNoNoNoYes

Verpackung

SN65LBC182DSN65LBC182DG4SN65LBC182DRSN65LBC182DRG4SN65LBC182PSN65LBC182PE4
N123456
Pin888888
Package TypeDDDDPP
Industry STD TermSOICSOICSOICSOICPDIPPDIP
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDIP-TR-PDIP-T
Package QTY7575250025005050
CarrierTUBETUBELARGE T&RLARGE T&RTUBETUBE
Device Marking6LB1826LB1826LB1826LB18265LBC18265LBC182
Width (mm)3.913.913.913.916.356.35
Length (mm)4.94.94.94.99.819.81
Thickness (mm)1.581.581.581.583.93.9
Pitch (mm)1.271.271.271.272.542.54
Max Height (mm)1.751.751.751.755.085.08
Mechanical DataHerunterladenHerunterladenHerunterladenHerunterladenHerunterladenHerunterladen

Parameter

Parameters / ModelsSN65LBC182D
SN65LBC182D
SN65LBC182DG4
SN65LBC182DG4
SN65LBC182DR
SN65LBC182DR
SN65LBC182DRG4
SN65LBC182DRG4
SN65LBC182P
SN65LBC182P
SN65LBC182PE4
SN65LBC182PE4
Common Mode Range-7 to 12-7 to 12-7 to 12-7 to 12-7 to 12-7 to 12
DuplexHalfHalfHalfHalfHalfHalf
Fail SafeOpenOpenOpenOpenOpenOpen
Fault Protection, V-10 to 15-10 to 15-10 to 15-10 to 15-10 to 15-10 to 15
HBM ESD, kV151515151515
ICC(Max), mA303030303030
IEC 61000-4-2 Contact, +/- kV888888
IsolatedNoNoNoNoNoNo
No. of RX111111
No. of TX111111
Number of Nodes128128128128128128
Operating Temperature Range, C-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85
Package GroupSOICSOICSOICSOICPDIPPDIP
RatingCatalogCatalogCatalogCatalogCatalogCatalog
Signaling Rate(Max), Mbps0.250.250.250.250.250.25
Supply Voltage(s)(Nom), V555555

Öko-Plan

SN65LBC182DSN65LBC182DG4SN65LBC182DRSN65LBC182DRG4SN65LBC182PSN65LBC182PE4
RoHSCompliantCompliantCompliantCompliantCompliantCompliant
Pb FreeYesYes

Anwendungshinweise

  • RS-485 for E-Meter Applications (Rev. A)
    PDF, 311 Kb, Revision: A, Datei veröffentlicht: Aug 6, 2004
    This application report discusses the best practices for designing energy meter communication circuits using the RS-485 standard. Component selection and performance tradeoffs are covered with reference to relevant standards such as IEC 61036 and DL/T 645. Reference design details are provided to help energy meter engineers successfully complete their own circuit designs.
  • The RS-485 Unit Load and Maximum Number of Bus Connections
    PDF, 197 Kb, Datei veröffentlicht: Mar 15, 2004
    The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.

Modellreihe

Herstellerklassifikation

  • Semiconductors> Interface> RS-485 Transceivers