Datasheet Texas Instruments OPA547 — Datenblatt
Hersteller | Texas Instruments |
Serie | OPA547 |
Hochspannungs- und Hochstrom-Operationsverstärker mit Abschaltfunktion
Datenblätter
High-Voltage, High-Current Operational Amplifier datasheet
PDF, 925 Kb, Revision: F, Datei veröffentlicht: Jul 21, 2005
Auszug aus dem Dokument
Preise
Status
OPA547F | OPA547F/500 | OPA547F/500G3 | OPA547FKTWT | OPA547FKTWTG3 | OPA547T | OPA547T-1 | OPA547T-1G3 | OPA547TG3 | |
---|---|---|---|---|---|---|---|---|---|
Lifecycle Status | Obsolete (Manufacturer has discontinued the production of the device) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes | No | No | No | No | No | No | Yes | No |
Verpackung
OPA547F | OPA547F/500 | OPA547F/500G3 | OPA547FKTWT | OPA547FKTWTG3 | OPA547T | OPA547T-1 | OPA547T-1G3 | OPA547TG3 | |
---|---|---|---|---|---|---|---|---|---|
N | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
Pin | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
Package Type | KTW | KTW | KTW | KTW | KTW | KVT | KC | KC | KVT |
Industry STD Term | TO-263 | TO-263 | TO-263 | TO-263 | TO-263 | TO-220 | TO-220 | TO-220 | TO-220 |
JEDEC Code | R-PSFM-G | R-PSFM-G | R-PSFM-G | R-PSFM-G | R-PSFM-G | R-PZFM-T | R-PSFM-T | R-PSFM-T | R-PZFM-T |
Width (mm) | 8.89 | 8.89 | 8.89 | 8.89 | 8.89 | 8.34 | 8.38 | 8.38 | 8.34 |
Length (mm) | 10.1 | 10.1 | 10.1 | 10.1 | 10.1 | 10.16 | 10.17 | 10.17 | 10.16 |
Thickness (mm) | 4.44 | 4.44 | 4.44 | 4.44 | 4.44 | 4.6 | 4.58 | 4.58 | 4.6 |
Pitch (mm) | 1.27 | 1.27 | 1.27 | 1.27 | 1.27 | 1.27 | 1.27 | 1.27 | 1.27 |
Max Height (mm) | 4.65 | 4.65 | 4.65 | 4.65 | 4.65 | 4.7 | 4.7 | 4.7 | 4.7 |
Mechanical Data | Herunterladen | Herunterladen | Herunterladen | Herunterladen | Herunterladen | Herunterladen | Herunterladen | Herunterladen | Herunterladen |
Package QTY | 500 | 500 | 250 | 250 | 50 | 50 | 50 | 50 | |
Carrier | LARGE T&R | LARGE T&R | SMALL T&R | SMALL T&R | TUBE | TUBE | TUBE | TUBE | |
Device Marking | OPA547F | OPA547F | OPA547F | OPA547F | OPA547T | OPA547T | OPA547T | OPA547T |
Parameter
Parameters / Models | OPA547F | OPA547F/500 | OPA547F/500G3 | OPA547FKTWT | OPA547FKTWTG3 | OPA547T | OPA547T-1 | OPA547T-1G3 | OPA547TG3 |
---|---|---|---|---|---|---|---|---|---|
Additional Features | Adj Current Limit Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown | Adj Current Limit,Shutdown |
Approx. Price (US$) | 5.75 | 1ku | ||||||||
Architecture | Bipolar | Bipolar | Bipolar | Bipolar | Bipolar | Bipolar | Bipolar | Bipolar | Bipolar |
CMRR(Min), dB | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
CMRR(Min)(dB) | 80 | ||||||||
CMRR(Typ), dB | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | |
CMRR(Typ)(dB) | 95 | ||||||||
GBW(Typ), MHz | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
GBW(Typ)(MHz) | 1 | ||||||||
Input Bias Current(Max), pA | 500000 | 500000 | 500000 | 500000 | 500000 | 500000 | 500000 | 500000 | |
Input Bias Current(Max)(pA) | 500000 | ||||||||
Iq per channel(Max), mA | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | |
Iq per channel(Max)(mA) | 15 | ||||||||
Iq per channel(Typ), mA | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
Iq per channel(Typ)(mA) | 10 | ||||||||
Number of Channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Number of Channels(#) | 1 | ||||||||
Offset Drift(Typ), uV/C | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
Offset Drift(Typ)(uV/C) | 25 | ||||||||
Operating Temperature Range, C | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | |
Operating Temperature Range(C) | -40 to 85 | ||||||||
Output Current(Typ), mA | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |
Output Current(Typ)(mA) | 500 | ||||||||
Package Group | DDPAK/TO-263 | DDPAK/TO-263 | DDPAK/TO-263 | DDPAK/TO-263 | DDPAK/TO-263 | TO-220 | TO-220 | TO-220 | TO-220 |
Package Size: mm2:W x L, PKG | 7DDPAK/TO-263: 154 mm2: 15.24 x 10.1(DDPAK/TO-263) | 7DDPAK/TO-263: 154 mm2: 15.24 x 10.1(DDPAK/TO-263) | 7DDPAK/TO-263: 154 mm2: 15.24 x 10.1(DDPAK/TO-263) | 7DDPAK/TO-263: 154 mm2: 15.24 x 10.1(DDPAK/TO-263) | See datasheet (TO-220) | See datasheet (TO-220) | See datasheet (TO-220) | See datasheet (TO-220) | |
Package Size: mm2:W x L (PKG) | See datasheet (TO-220) | ||||||||
Rail-to-Rail | In to V- | In to V- | In to V- | In to V- | In to V- | In to V- | In to V- | In to V- | In to V- |
Rating | Catalog | Catalog | Catalog | Catalog | Catalog | Catalog | Catalog | Catalog | Catalog |
Slew Rate(Typ), V/us | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
Slew Rate(Typ)(V/us) | 6 | ||||||||
Total Supply Voltage(Max), +5V=5, +/-5V=10 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | 60 | |
Total Supply Voltage(Max)(+5V=5, +/-5V=10) | 60 | ||||||||
Total Supply Voltage(Min), +5V=5, +/-5V=10 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | |
Total Supply Voltage(Min)(+5V=5, +/-5V=10) | 8 | ||||||||
Vos (Offset Voltage @ 25C)(Max), mV | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
Vos (Offset Voltage @ 25C)(Max)(mV) | 5 |
Öko-Plan
OPA547F | OPA547F/500 | OPA547F/500G3 | OPA547FKTWT | OPA547FKTWTG3 | OPA547T | OPA547T-1 | OPA547T-1G3 | OPA547TG3 | |
---|---|---|---|---|---|---|---|---|---|
RoHS | Not Compliant | Compliant | Compliant | Compliant | Compliant | Compliant | Compliant | Compliant | Compliant |
Pb Free | No |
Anwendungshinweise
- Power Amplifier Stress and Power Handling LimitationsPDF, 55 Kb, Datei veröffentlicht: Sep 27, 2000
To achieve reliable power amplifier designs you must consider the stress on the amplifier compared to its power handling limitations. Power handling limits are specified by the Safe Operating Area (SOA) curves of the power amp. Stress on the amplifier depends on amplifier load and signal conditions which can be evaluated with straightforward techniques. - DC MOTOR SPEED CONTROLLER: Control a DC Motor without Tachometer FeedbackPDF, 50 Kb, Datei veröffentlicht: Sep 27, 2000
DC motor speed is often regulated with a closed-loop speed controller using tachometer feedback. It is possible, however, to control dc motor speed without tachometer feedback. - MTTF, Failrate, Reliability, and Life TestingPDF, 51 Kb, Datei veröffentlicht: Oct 4, 2000
At Burr-Brown, we characterize and qualify the reliability of our devices through high temperature life testing. The results of this testing are quantified with such values as MTTF and failure rate. This information can be very valuable when used for comparative purposes or applied to reliablility calculations. However, this information loses its worth if it is not precisely understood and appropr
Modellreihe
Serie: OPA547 (9)
Herstellerklassifikation
- Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Power Op Amps