Datasheet Texas Instruments OPA541 — Datenblatt

HerstellerTexas Instruments
SerieOPA541
Datasheet Texas Instruments OPA541

Monolithischer Hochleistungs-Operationsverstärker

Datenblätter

OPA541 High Power Monolithic Operational Amplifier datasheet
PDF, 409 Kb, Revision: B, Datei veröffentlicht: Apr 7, 2015
Auszug aus dem Dokument

Preise

Status

OPA541-WOPA541AMOPA541AM-BIOPA541APOPA541APG3OPA541BMOPA541SMOPA541SM-BI
Lifecycle StatusActive (Recommended for new designs)NRND (Not recommended for new designs)NRND (Not recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)NRND (Not recommended for new designs)NRND (Not recommended for new designs)Obsolete (Manufacturer has discontinued the production of the device)
Manufacture's Sample AvailabilityNoNoNoNoNoNoNoNo

Verpackung

OPA541-WOPA541AMOPA541AM-BIOPA541APOPA541APG3OPA541BMOPA541SMOPA541SM-BI
N12345678
Package TypeYSLMFZZ030KVKVLMFLMFLMF
Pin881111888
Industry STD TermTO-CANZZ (BB)TO-220TO-220TO-CANTO-CANTO-CAN
JEDEC CodeO-MBCY-WO-MBCY-WR-PZFM-TR-PZFM-TO-MBCY-WO-MBCY-WO-MBCY-W
Package QTY125251818
CarrierTUBETUBETUBETUBETUBE
Device MarkingOPA541AMOPA541APOPA541APOPA541BMOPA541SM
Width (mm)25.410.710.725.425.425.4
Length (mm)38.8620.0220.0238.8638.8638.86
Thickness (mm)7.114.54.57.117.117.11
Pitch (mm)6.351.71.76.356.356.35
Max Height (mm)7.624.624.627.627.627.62
Mechanical DataHerunterladenHerunterladenHerunterladenHerunterladenHerunterladenHerunterladenHerunterladen

Parameter

Parameters / ModelsOPA541-W
OPA541-W
OPA541AM
OPA541AM
OPA541AM-BI
OPA541AM-BI
OPA541AP
OPA541AP
OPA541APG3
OPA541APG3
OPA541BM
OPA541BM
OPA541SM
OPA541SM
OPA541SM-BI
OPA541SM-BI
Additional FeaturesAdj Current LimitAdj Current LimitAdj Current LimitAdj Current LimitAdj Current LimitAdj Current LimitAdj Current LimitAdj Current Limit
Approx. Price (US$)12.60 | 1ku12.60 | 1ku12.60 | 1ku
ArchitectureFETFETFETFETFETFETFETFET
CMRR(Min), dB9595959595
CMRR(Min)(dB)959595
CMRR(Typ), dB113113113113113
CMRR(Typ)(dB)113113113
GBW(Typ), MHz22222
GBW(Typ)(MHz)222
Input Bias Current(Max), pA5050505050
Input Bias Current(Max)(pA)505050
Iq per channel(Max), mA2525252525
Iq per channel(Max)(mA)252525
Iq per channel(Typ), mA2020202020
Iq per channel(Typ)(mA)202020
Number of Channels11111
Number of Channels(#)111
Offset Drift(Typ), uV/C1515151515
Offset Drift(Typ)(uV/C)151515
Operating Temperature Range, C-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85
Operating Temperature Range(C)-25 to 85-25 to 85-25 to 85
Output Current(Typ), mA1000010000100001000010000
Output Current(Typ)(mA)100001000010000
Package GroupWAFERSALETO-220TO-220
WAFERSALE
TO-220TO-220TO-220TO-220TO-220
WAFERSALE
Package Size: mm2:W x L, PKGSee datasheet (TO-220)See datasheet (TO-220)See datasheet (TO-220)See datasheet (TO-220)See datasheet (TO-220)
Package Size: mm2:W x L (PKG)See datasheet (TO-220)See datasheet (TO-220)See datasheet (TO-220)
Rail-to-RailNoNoNoNoNoNoNoNo
RatingCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalog
Slew Rate(Typ), V/us1010101010
Slew Rate(Typ)(V/us)101010
Total Supply Voltage(Max), +5V=5, +/-5V=107070707070
Total Supply Voltage(Max)(+5V=5, +/-5V=10)707070
Total Supply Voltage(Min), +5V=5, +/-5V=102020202020
Total Supply Voltage(Min)(+5V=5, +/-5V=10)202020
Vos (Offset Voltage @ 25C)(Max), mV11111
Vos (Offset Voltage @ 25C)(Max)(mV)111

Öko-Plan

OPA541-WOPA541AMOPA541AM-BIOPA541APOPA541APG3OPA541BMOPA541SMOPA541SM-BI
RoHSNot CompliantCompliantNot CompliantCompliantCompliantCompliantCompliantNot Compliant
Pb FreeYesYesYesNoNoNo

Anwendungshinweise

  • Improve OPA541 Current-Limit Stability
    PDF, 31 Kb, Datei veröffentlicht: Oct 2, 2000
    OPA541 is the industry's highest performance monolithic power amplifier. It can operate on В±40V power supplies and put out 5A continuously (10A peak). Internal current-limit circuitry can be user-programmed with a single external resistor to protect the amplifier and load from fault conditions.
  • Mounting Considerations for TO-3 Packages
    PDF, 73 Kb, Datei veröffentlicht: Sep 27, 2000
    Proper mounting of TO-3 packages is required to assure rated performance and reliability. Although the procedures are simple, ignoring them can result in poor performance and catastrophic failure of the device.
  • MTTF, Failrate, Reliability, and Life Testing
    PDF, 51 Kb, Datei veröffentlicht: Oct 4, 2000
    At Burr-Brown, we characterize and qualify the reliability of our devices through high temperature life testing. The results of this testing are quantified with such values as MTTF and failure rate. This information can be very valuable when used for comparative purposes or applied to reliablility calculations. However, this information loses its worth if it is not precisely understood and appropr
  • Power Amplifier Stress and Power Handling Limitations
    PDF, 55 Kb, Datei veröffentlicht: Sep 27, 2000
    To achieve reliable power amplifier designs you must consider the stress on the amplifier compared to its power handling limitations. Power handling limits are specified by the Safe Operating Area (SOA) curves of the power amp. Stress on the amplifier depends on amplifier load and signal conditions which can be evaluated with straightforward techniques.

Modellreihe

Herstellerklassifikation

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Power Op Amps