Datasheet Texas Instruments OPA1679 — Datenblatt

HerstellerTexas Instruments
SerieOPA1679
Datasheet Texas Instruments OPA1679

Verzerrungsarmer Audio-Operationsverstärker

Datenblätter

OPA167x Low-Distortion Audio Operational Amplifiers datasheet
PDF, 1.8 Mb, Datei veröffentlicht: Feb 23, 2017
Auszug aus dem Dokument

Preise

Status

OPA1679IDROPA1679IPWR
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesYes

Verpackung

OPA1679IDROPA1679IPWR
N12
Pin1414
Package TypeDPW
Industry STD TermSOICTSSOP
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY25002000
CarrierLARGE T&RLARGE T&R
Device MarkingOPA1679OPA1679
Width (mm)3.914.4
Length (mm)8.655
Thickness (mm)1.581
Pitch (mm)1.27.65
Max Height (mm)1.751.2
Mechanical DataHerunterladenHerunterladen

Parameter

Parameters / ModelsOPA1679IDR
OPA1679IDR
OPA1679IPWR
OPA1679IPWR
CMRR(Min), dB100100
CMRR(Typ), dB110110
GBW(Typ), MHz1616
Iq per channel(Max), mA2.52.5
Iq per channel(Typ), mA22
Number of Channels44
Operating Temperature Range, C-40 to 85-40 to 85
Output Current(Typ), mA5050
Package GroupSOICTSSOP
Package Size: mm2:W x L, PKG14SOIC: 52 mm2: 6 x 8.65(SOIC)14TSSOP: 32 mm2: 6.4 x 5(TSSOP)
Rail-to-RailOutOut
RatingCatalogCatalog
Slew Rate(Typ), V/us99
THD + N @ 1 kHz(Typ), %0.00010.0001
Total Supply Voltage(Max), +5V=5, +/-5V=103636
Total Supply Voltage(Min), +5V=5, +/-5V=104.54.5
Vn at 1kHz(Typ), nV/rtHz4.54.5
Vos (Offset Voltage @ 25C)(Max), mV22

Öko-Plan

OPA1679IDROPA1679IPWR
RoHSCompliantCompliant

Anwendungshinweise

  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revision: A, Datei veröffentlicht: Mar 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Serie: OPA1679 (2)

Herstellerklassifikation

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Audio Op Amps