Datasheet Texas Instruments OPA1013 — Datenblatt

HerstellerTexas Instruments
SerieOPA1013
Datasheet Texas Instruments OPA1013

Präziser Dual-Operationsverstärker mit einer Versorgung

Datenblätter

Precision, Single-Supply Dual Operational Amplifier datasheet
PDF, 147 Kb, Datei veröffentlicht: Sep 27, 2000
Auszug aus dem Dokument

Preise

Status

OPA1013CN8OPA1013CN8G4OPA1013DN8OPA1013DN8G4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoNoNoNo

Verpackung

OPA1013CN8OPA1013CN8G4OPA1013DN8OPA1013DN8G4
N1234
Pin8888
Package TypePPPP
Industry STD TermPDIPPDIPPDIPPDIP
JEDEC CodeR-PDIP-TR-PDIP-TR-PDIP-TR-PDIP-T
Package QTY50505050
CarrierTUBETUBETUBETUBE
Device MarkingOPA1013COPA1013COPA1013DOPA1013D
Width (mm)6.356.356.356.35
Length (mm)9.819.819.819.81
Thickness (mm)3.93.93.93.9
Pitch (mm)2.542.542.542.54
Max Height (mm)5.085.085.085.08
Mechanical DataHerunterladenHerunterladenHerunterladenHerunterladen

Parameter

Parameters / ModelsOPA1013CN8
OPA1013CN8
OPA1013CN8G4
OPA1013CN8G4
OPA1013DN8
OPA1013DN8
OPA1013DN8G4
OPA1013DN8G4
Additional FeaturesN/AN/AN/AN/A
ArchitectureBipolarBipolarBipolarBipolar
CMRR(Min), dB97979797
CMRR(Typ), dB104104104104
GBW(Typ), MHz0.50.50.50.5
Input Bias Current(Max), pA30000300003000030000
Iq per channel(Max), mA0.550.550.550.55
Iq per channel(Typ), mA0.340.340.340.34
Number of Channels2222
Offset Drift(Typ), uV/C0.40.40.40.4
Operating Temperature Range, C0 to 700 to 700 to 700 to 70
Output Current(Typ), mA30303030
Package GroupPDIPPDIPPDIPPDIP
Package Size: mm2:W x L, PKGSee datasheet (PDIP)See datasheet (PDIP)See datasheet (PDIP)See datasheet (PDIP)
Rail-to-RailIn to V-,OutIn to V-,OutIn to V-,OutIn to V-,Out
RatingCatalogCatalogCatalogCatalog
Slew Rate(Typ), V/us0.350.350.350.35
Total Supply Voltage(Max), +5V=5, +/-5V=1036363636
Total Supply Voltage(Min), +5V=5, +/-5V=104444
Vn at 1kHz(Typ), nV/rtHz25252525
Vos (Offset Voltage @ 25C)(Max), mV0.30.30.30.3

Öko-Plan

OPA1013CN8OPA1013CN8G4OPA1013DN8OPA1013DN8G4
RoHSCompliantCompliantCompliantCompliant

Anwendungshinweise

  • Single-Supply, Low-Power Measurements Of Bridge Networks
    PDF, 26 Kb, Datei veröffentlicht: Sep 27, 2000
    Bridge sensor measurements often need to be made in systems operating on a single 5V power supply. An OPA1013 dual op amp along with a REF200 current source, makes an excellent bridge measurement system which features low power single-supply 5V operation and immunity to power supply variations. One OPA1013 dual op amp is used as a two-op-amp instrumentation amplifier. A second OPA1013 is used with
  • Diode-Based Temperature Measurement
    PDF, 44 Kb, Datei veröffentlicht: Sep 27, 2000
    Diodes are frequently used as temperature sensors in a wide variety of moderate-precision temperature measurement applications. The relatively high temperature coefficient of about -2mV/В°C is fairly linear. To make a temperature measurement system with a diode requires excitation, offsetting, and amplification. The circuitry can be quite simple. This Bulletin contains a collection of circuits
  • Implementation and Applications of Current Sources and Current Receivers
    PDF, 427 Kb, Datei veröffentlicht: Sep 27, 2000
    This application guide is intended as a source book for the design and application of: Current sourcesCurrent sinksFloating current sourcesVoltage-to-current converters(transconductance amplifiers)Current-to-current converters (current mirrors)Current-to-voltage converters(transimpedance amplifiers)
  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revision: A, Datei veröffentlicht: Mar 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Herstellerklassifikation

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Precision Op Amps