Datasheet Texas Instruments LMV932-N — Datenblatt

HerstellerTexas Instruments
SerieLMV932-N
Datasheet Texas Instruments LMV932-N

Zwei 1,8-V-RRIO-Operationsverstärker

Datenblätter

LMV93x-N Single, Dual, Quad 1.8-V, RRIO Operational Amplifiers datasheet
PDF, 1.7 Mb, Revision: P, Datei veröffentlicht: May 7, 2017
Auszug aus dem Dokument

Preise

Status

LMV932MALMV932MA/NOPBLMV932MAXLMV932MAX/NOPBLMV932MMLMV932MM/NOPBLMV932MMX/NOPB
Lifecycle StatusNRND (Not recommended for new designs)Active (Recommended for new designs)NRND (Not recommended for new designs)Active (Recommended for new designs)NRND (Not recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoYesNoYesYesYesNo

Verpackung

LMV932MALMV932MA/NOPBLMV932MAXLMV932MAX/NOPBLMV932MMLMV932MM/NOPBLMV932MMX/NOPB
N1234567
Pin8888888
Package TypeDDDDDGKDGKDGK
Industry STD TermSOICSOICSOICSOICVSSOPVSSOPVSSOP
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY959525002500100010003500
CarrierTUBETUBELARGE T&RLARGE T&RSMALL T&RSMALL T&RLARGE T&R
Device Marking32MA32MALMV932MAA86AA86AA86A
Width (mm)3.913.913.913.91333
Length (mm)4.94.94.94.9333
Thickness (mm)1.581.581.581.58.97.97.97
Pitch (mm)1.271.271.271.27.65.65.65
Max Height (mm)1.751.751.751.751.071.071.07
Mechanical DataHerunterladenHerunterladenHerunterladenHerunterladenHerunterladenHerunterladenHerunterladen

Parameter

Parameters / ModelsLMV932MA
LMV932MA
LMV932MA/NOPB
LMV932MA/NOPB
LMV932MAX
LMV932MAX
LMV932MAX/NOPB
LMV932MAX/NOPB
LMV932MM
LMV932MM
LMV932MM/NOPB
LMV932MM/NOPB
LMV932MMX/NOPB
LMV932MMX/NOPB
Additional FeaturesN/AN/AN/AN/AN/AN/AN/A
ArchitectureBipolarBipolarBipolarBipolarBipolarBipolarBipolar
CMRR(Min), dB60606060606060
CMRR(Typ), dB86868686868686
GBW(Typ), MHz1.51.51.51.51.51.51.5
Input Bias Current(Max), pA35000350003500035000350003500035000
Iq per channel(Max), mA0.230.230.230.230.230.230.23
Iq per channel(Typ), mA0.1160.1160.1160.1160.1160.1160.116
Number of Channels2222222
Offset Drift(Typ), uV/C5.55.55.55.55.55.55.5
Operating Temperature Range, C-40 to 125-40 to 125-40 to 125-40 to 125-40 to 125-40 to 125-40 to 125
Output Current(Typ), mA65656565656565
Package GroupSOICSOICSOICSOICVSSOPVSSOPVSSOP
Package Size: mm2:W x L, PKG8SOIC: 29 mm2: 6 x 4.9(SOIC)8SOIC: 29 mm2: 6 x 4.9(SOIC)8SOIC: 29 mm2: 6 x 4.9(SOIC)8SOIC: 29 mm2: 6 x 4.9(SOIC)8VSSOP: 15 mm2: 4.9 x 3(VSSOP)8VSSOP: 15 mm2: 4.9 x 3(VSSOP)8VSSOP: 15 mm2: 4.9 x 3(VSSOP)
Rail-to-RailIn,OutIn,OutIn,OutIn,OutIn,OutIn,OutIn,Out
RatingCatalogCatalogCatalogCatalogCatalogCatalogCatalog
Slew Rate(Typ), V/us0.420.420.420.420.420.420.42
Total Supply Voltage(Max), +5V=5, +/-5V=105.55.55.55.55.55.55.5
Total Supply Voltage(Min), +5V=5, +/-5V=101.81.81.81.81.81.81.8
Vn at 1kHz(Typ), nV/rtHz50505050505050
Vos (Offset Voltage @ 25C)(Max), mV5.55.55.55.55.55.55.5

Öko-Plan

LMV932MALMV932MA/NOPBLMV932MAXLMV932MAX/NOPBLMV932MMLMV932MM/NOPBLMV932MMX/NOPB
RoHSSee ti.comCompliantSee ti.comCompliantSee ti.comCompliantCompliant

Anwendungshinweise

  • AN-1515 A Comprehensive Study of the Howland Current Pump (Rev. A)
    PDF, 165 Kb, Revision: A, Datei veröffentlicht: Apr 26, 2013
    It is well known to analog experts that you can use the positive and negative inputs of an operationalamplifier to make a high-impedance current source (current pump) using a conventional operationalamplifier (op amp). This basic circuit can put out both + and - output current (or zero current) into variousloads. The theory is simple. But the practical problems involved are not so simple or
  • Effect of Heavy Loads on Accuracy and Linearity of Op Amp Circuits (Rev. B)
    PDF, 81.7 Mb, Revision: B, Datei veröffentlicht: Apr 22, 2013
    This application report discusses the effect of heavy loads on the accuracy and linearity of operationalamplifier circuits.

Modellreihe

Herstellerklassifikation

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> General-Purpose Op Amps