Datasheet Texas Instruments LMP7721 — Datenblatt
Hersteller | Texas Instruments |
Serie | LMP7721 |
3 Femtoampere-Eingangsvorspannungs-Strompräzisionsverstärker
Datenblätter
LMP7721 3-Femtoampere Input Bias Current Precision Amplifier datasheet
PDF, 1.0 Mb, Revision: E, Datei veröffentlicht: Dec 15, 2014
Auszug aus dem Dokument
Preise
Status
LMP7721MA/NOPB | LMP7721MAX/NOPB | |
---|---|---|
Lifecycle Status | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | No | Yes |
Verpackung
LMP7721MA/NOPB | LMP7721MAX/NOPB | |
---|---|---|
N | 1 | 2 |
Pin | 8 | 8 |
Package Type | D | D |
Industry STD Term | SOIC | SOIC |
JEDEC Code | R-PDSO-G | R-PDSO-G |
Package QTY | 95 | 2500 |
Carrier | TUBE | LARGE T&R |
Device Marking | LMP77 | 21MA |
Width (mm) | 3.91 | 3.91 |
Length (mm) | 4.9 | 4.9 |
Thickness (mm) | 1.58 | 1.58 |
Pitch (mm) | 1.27 | 1.27 |
Max Height (mm) | 1.75 | 1.75 |
Mechanical Data | Herunterladen | Herunterladen |
Parameter
Parameters / Models | LMP7721MA/NOPB | LMP7721MAX/NOPB |
---|---|---|
Additional Features | N/A | N/A |
Architecture | CMOS | CMOS |
CMRR(Min), dB | 84 | 84 |
CMRR(Typ), dB | 100 | 100 |
GBW(Typ), MHz | 17 | 17 |
Input Bias Current(Max), pA | 0.02 | 0.02 |
Iq per channel(Max), mA | 1.7 | 1.7 |
Iq per channel(Typ), mA | 1.3 | 1.3 |
Number of Channels | 1 | 1 |
Offset Drift(Typ), uV/C | 1.5 | 1.5 |
Operating Temperature Range, C | -40 to 125 | -40 to 125 |
Output Current(Typ), mA | 22 | 22 |
Package Group | SOIC | SOIC |
Package Size: mm2:W x L, PKG | 8SOIC: 29 mm2: 6 x 4.9(SOIC) | 8SOIC: 29 mm2: 6 x 4.9(SOIC) |
Rail-to-Rail | In to V-,Out | In to V-,Out |
Rating | Catalog | Catalog |
Slew Rate(Typ), V/us | 10.5 | 10.5 |
Total Supply Voltage(Max), +5V=5, +/-5V=10 | 5.5 | 5.5 |
Total Supply Voltage(Min), +5V=5, +/-5V=10 | 1.8 | 1.8 |
Vn at 1kHz(Typ), nV/rtHz | 6.5 | 6.5 |
Vos (Offset Voltage @ 25C)(Max), mV | 0.15 | 0.15 |
Öko-Plan
LMP7721MA/NOPB | LMP7721MAX/NOPB | |
---|---|---|
RoHS | Compliant | Compliant |
Anwendungshinweise
- AN-1798 Designing with Electro-Chemical Sensors (Rev. C)PDF, 62 Kb, Revision: C, Datei veröffentlicht: May 1, 2013
As early as 1950, electro-chemical sensors were used for oxygen (gas) monitoring; however, with increasing concerns about personal safety, the demand for portable electro-chemical sensors has dramatically increased. Today, electro-chemical sensors are commonly used in portable equipment todetect different toxic gases. - AN-1852 Designing With pH Electrodes (Rev. A)PDF, 115 Kb, Revision: A, Datei veröffentlicht: May 1, 2013
A pH electrode measures hydrogen ion (H+) activity and produces an electrical potential or voltage. Theoperation of the pH electrode is based on the principle that an electric potential develops when two liquidsof different pH come into contact at opposite sides of a thin glass membrane. This was originallydiscovered in 1906 by Max Cremer [1]. His discovery laid the foundation for Fritz Habe
Modellreihe
Serie: LMP7721 (2)
Herstellerklassifikation
- Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Precision Op Amps